Mechanical Ambient Conditions; Chemical / Mechanical Active Substances; Table 3: Mechanical Ambient Conditions; Table 4: Chemical / Mechanical Active Substances - KEB COMBIVERT P6 Instructions For Use Manual

Installation p6 pitch inverter 18/19/23p6 housing g, r
Hide thumbs Also See for COMBIVERT P6:
Table of Contents

Advertisement

OPERATING CONDITIONS

3.1.2 Mechanical ambient conditions

Storage
Vibration limits
Shock limits
Transport
Vibration limits
Shock limits
Operation
Vibration limits
Shock limits
Table 3:
Mechanical ambient conditions
Not tested.
1)

3.1.3 Chemical / mechanical active substances

Storage
Gases
Contamination
Solids
Transport
Gases
Contamination
Solids
Operation
Gases
Contamination
Solids
Table 4:
Chemical / mechanical active substances
Standard
Class
1M3
EN 60721-3-1
EN 61373
Germ. Lloyd, 7-2
1M3
EN 60721-3-1
Standard
Class
EN 60721-3-2
2M1
EN 61373
Germ. Lloyd, 7-2
2M1
EN 60721-3-2
Standard
Class
3M4
EN 60721-3-3
EN 61800-5-1
EN 61373
Germ. Lloyd, 7-2
3M4
EN 60721-3-3
Standard
Class
1C2
EN 60721-3-1
1S2
Standard
Class
2C2
EN 60721-3-2
2S2
Standard
Class
3C2
EN 60721-3-3
3S2
Descriptions
Vibration amplitude 3.0 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
Railway
100 m/s²; 11 ms
Descriptions
Vibration amplitude 3.5 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
(acceleration amplitude 15 m/s² (200...500 Hz))
Railway
100 m/s²; 11 ms
Descriptions
Vibration amplitude 3.0 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
Vibration amplitude 0.075 mm (10...57 Hz)
Acceleration amplitude 10 m/s² (57...150 Hz)
Railway
100 m/s²; 11 ms
Descriptions
Descriptions
Descriptions
1)