PRODUCT DESCRIPTION

2.4 Options

The pitch drive controller can be equipped with the following options:
24
Brake supply and control 24 V (18 / 19P6) or 50...300 V (18 / 19 / 23P6)
Output 24 V / 4.2 A can be used for customer components if no 24 V brake is con-
nected (18 / 19P6)
Output 24 V / 3 A can be used for customer components (23P6)
External braking resistor for high power
Integrated heating resistor for cold climate version and as moisture/condensation
protection
Humidity sensor, mounting orientation sensor, analog inputs
Fieldbus interface CANopen, ProfiBus, Interbus, PROFINET, POWERLINK, EtherCAT
Fan rotation axes either in the X, Y or Z direction (to match with the mounting ori-
entation)
Extended pitch library for the built-in PLC with the following function blocks:
Reaction on Grid Loss (LVRT)
Monitoring of ultracapacitors
Monitoring of batteries
Monitoring of the fuses and cabling to the energy storage
Measurement of capacitance and internal resistance of ultracapacitors
Controlled discharge of the ultracapacitors (for service)
Error memory and real-time clock
Data logger