Terminal Block X1B; Mains Connection; Figure 10: Terminal Strip X1B; Figure 11: Mains Connection - KEB COMBIVERT P6 Instruction Manual

Hide thumbs Also See for COMBIVERT P6:
Table of Contents

Advertisement

Power unit

4.2.1.2 Terminal block X1B

Terminals
U, V, W
F2, U, V, W
BT+, BT-
B+, B-
T1, T2
HB+, HB-
BTM
PE,
Figure 10:
4.2.2

Mains connection

Terminal block X1A
L1
L2
L3 PE
Figure 11:
26
Function
Motor output 3-phase
Connection for DC motor
Connection for batteries/
ultracaps
Output for brake 24 VDC
Input for temperature sen-
sor
Output for brake
150...300 Vdc (option)
DC voltage measurement
input
protection-/functional earth
Terminal strip X1B
F1-F3
Q1
DR
5
6
3
4
1
2
Mains connection
cross section [mm²]
4x M6; Depth of thread 10 mm;
Tightening torque 4.8 Nm
Name
L1, L2, L3
PE,
P6
F1-F3
L1
Q1
L2
L3
DR
Permissible cable
0.75...16
0.25...6
Description
Mains input 3-phase 400 V
Protective earth
Mains fuses
Power switch or mains contactor
(depending on application)
Mains choke (recommended; for
„Functional Safety" required)
Strip length
[mm]
18
15

Hide quick links: