Operating Conditions - KEB COMBIVERT P6 Instruction Manual

Hide thumbs Also See for COMBIVERT P6:
Table of Contents

Advertisement

Technical Data
3.2

Operating conditions

Definition acc.
Site altitude
Ambient conditions during operation
Climate
Mechanical
Contamination
Ambient conditions during transport
Climate
Mechanical
Contamination
Ambient conditions for the storage
Climate
Mechanical
Contamination
Protection degree
Environment
EMC definition according to
Emissions
Conducted emissions
Immunity
Burst - control cables + bus EN 61000-4-4
Surge - mains supply EN 61000-4-5
Cable-fed disturbances, induced
by high frequency fields
Electromagnetic fields EN 61000-4-3
Voltage fluctuations/ voltage dips EN 61000-2-1
Table 1:
20
EN 61800-2
EN 61800-5-1
Temperature
EN 60721-3-3
Humidity
Germ. Lloyd
Vibration
EN 60721-3-3
Gas
EN 60721-3-3
Solids
Temperature
EN 60721-3-2
Humidity
Vibration
Germ. Lloyd
EN 60721-3-2
Shock EN 60721-3-2
Gas
EN 60721-3-2
Solids
Temperature
EN 60721-3-1
Humidity
Vibration
Germ. Lloyd
EN 60721-3-1
Shock EN 60721-3-1
Gas
EN 60721-3-1
Solids
IEC 664-1
EN 61800-3
Radiated emissions
ESD EN 61000-4-2
Burst - mains supply EN 61000-4-4
EN 61000-4-6
Voltage unbalance EN 61000-2-4
Operating conditions
Standard
Standard/
class
3K3
3K3
Railway
EN 61373
Part 7-2
3M4
3C2
3S2
2K3
2K3
Railway
EN 61373
Part 7-2
2M1
2M1
2C2
2S2
1K4
1K3
Railway
EN 61373
Part 7-2
1M3
1M3
1C2
1S2
IP20
EN 60529
IP54
C2
C2
8 kV
4 kV
2 kV
2 kV
1 / 2 kV
10 V/m
10 V/m
3 %
Remarks
Inverter product standard: rated specifications
Inverter product standard: general safety
max. 3000 m above sea level
(with site altitude above 1000 m a current derating
of 1 % per 100 m must be taken into consideration)
extended to
18P6
-30...60°C -30...55°C (at heat sink)
-30...70°C -30...65°C (in the cabinet)
5...85 % (without condensation)
extended to -45...70°C
(without condensation)
extended to -45°C...70°C
(without condensation)
Inner part (cabinet side)
Through panel mounted heat sink side
Pollution degree 2
Inverter product standard:EMC
->limit value A according to EN 55011
->limit value A according to EN 55011
AD (air discharge)
CD (contact discharge)
Phase-phase / phase-ground
upon request