Mitsubishi Electric NZ2GF2B-60TCTT4 User Manual page 49

Cc-link ie field network temperature control module
Table of Contents

Advertisement

Device number
Temperature input
RWr13
Use prohibited
RWr14
Use prohibited
RWr15
Use prohibited
RWr16
Use prohibited
RWr17
Use prohibited
RWr18
Use prohibited
RWr19
Use prohibited
RWr1A
Use prohibited
RWr1B
Use prohibited
RWr1C
Use prohibited
RWr1D
Use prohibited
RWr1E
Use prohibited
RWr1F
Use prohibited
*1
Available only under the heating-cooling control (expanded mode). For details on the expanded mode, refer to the
following.
Page 147, Section 8.3.1 (3)
*2
Available only under the mix control (expanded mode). For details on the expanded mode, refer to the following.
Page 147, Section 8.3.1 (3)
(2) List of remote register (RWw) areas
Device number
Temperature input
RWw0
Use prohibited
RWw1
Use prohibited
RWw2
Use prohibited
Remote register (RWr)
Signal direction: Temperature control module  Master/local module
Standard control
CH4 Manipulated value (MV)
CH1 Self-tuning flag
CH2 Self-tuning flag
CH3 Self-tuning flag
CH4 Self-tuning flag
CH1 Manipulated value (MV)
for output with another analog
module
CH2 Manipulated value (MV)
for output with another analog
module
CH3 Manipulated value (MV)
for output with another analog
module
CH4 Manipulated value (MV)
for output with another analog
module
Use prohibited
Use prohibited
Use prohibited
Use prohibited
Remote register (RWw)
Signal direction: Master/local module  Temperature control module
Standard control
CH1 Temperature process
value for input with another
analog module (PV)
CH2 Temperature process
value for input with another
analog module (PV)
CH3 Temperature process
value for input with another
analog module (PV)
CHAPTER 3 SPECIFICATIONS
Heating-cooling control
CH4 Manipulated value for
CH4 Manipulated value (MV)
*1
heating (MVh)
CH1 Manipulated value for
CH1 Manipulated value for
cooling (MVc)
cooling (MVc)
CH2 Manipulated value for
CH2 Manipulated value for
cooling (MVc)
cooling (MVc)
CH3 Manipulated value for
CH3 Self-tuning flag
*1
cooling (MVc)
CH4 Manipulated value for
CH4 Self-tuning flag
*1
cooling (MVc)
CH1 Manipulated value of
CH1 Manipulated value of
heating (MVh) for output with
heating (MVh) for output with
another analog module
another analog module
CH2 Manipulated value of
CH2 Manipulated value of
heating (MVh) for output with
heating (MVh) for output with
another analog module
another analog module
CH3 Manipulated value of
CH3 Manipulated value (MV)
heating (MVh) for output with
for output with another analog
*1
module
another analog module
CH4 Manipulated value of
CH4 Manipulated value (MV)
heating (MVh) for output with
for output with another analog
*1
module
another analog module
CH1 Manipulated value of
CH1 Manipulated value of
cooling (MVc) for output with
cooling (MVc) for output with
another analog module
another analog module
CH2 Manipulated value of
CH2 Manipulated value of
cooling (MVc) for output with
cooling (MVc) for output with
another analog module
another analog module
CH3 Manipulated value of
cooling (MVc) for output with
Use prohibited
*1
another analog module
CH4 Manipulated value of
cooling (MVc) for output with
Use prohibited
*1
another analog module
Heating-cooling control
CH1 Temperature process
CH1 Temperature process
value for input with another
value for input with another
analog module (PV)
analog module (PV)
CH2 Temperature process
CH2 Temperature process
value for input with another
value for input with another
analog module (PV)
analog module (PV)
CH3 Temperature process
CH3 Temperature process
value for input with another
value for input with another
*1
analog module (PV)
analog module (PV)
Mix control
3
*2
*2
*2
Mix control
*2
47