(2) Examples of dividing timing
(a) Four timing
The following table shows two examples.
Example
CH1
CH2
Example 1
CH3
CH4
CH1
CH2
Example 2
CH3
CH4
The following shows the relationship between groups and the values (%) of CH Upper limit output limiter
(address: 105H, 135H, 165H, 195H).
CH□ Simultaneous temperature rise group setting
(address: 2D0H, 2D4H, 2D8H, 2DCH)
4
3
2
Example 1
0100 0011 0010 0001
CH4 CH3 CH2 CH1
4
0
2
Example 2
0100 0000 0010 0001
CH4 CH3 CH2 CH1
Whether to perform the output or not for the group 0 can be
set by stopping the operation in the corresponding channel.
In Example 2, the maximum number of groups is four; therefore, timing is divided into four timing. Because no
channel is set for Group 3, no channel starts transistor output at the timing for Group 3.
Channel
Group 1
Group 2
Group 3
Group 4
Group 1
Group 2
Not divided
Group 4
Divided into
1
H
4 groups
1
H
Divided into
4 groups
Group
Group 1
Group 2
25%
25%
CH1
CH2
Group 1
Group 2
25%
25%
CH1
CH2
100% (when a default value is set)
CH3
CHAPTER 8 FUNCTIONS
Group 3
Group 4
25%
25%
CH3
CH4
Group 3
Group 4
25%
25%
CH4
195
8