Inspecting Cutterblade Hardware
Inspect blade attachment hardware each time blades are
changed.
1. Check and replace bolts under the following conditions:
a. Bolt has been removed and reinstalled five times.
b. Head (A) is worn flush with bearing surface
of blade.
c. Diameter of bolt neck is worn (B) to 1/8 in. (3 mm)
or less.
d. Bolt is cracked (C).
e. Bolt is visibly distorted (D).
f.
Bolt shows evidence of interference (E) with
adjacent parts.
147910
MAINTENANCE AND SERVICING
147
Figure 4.55: Cutterblade Bolts
Revision A