To replace the MorphoWave
Turn off the entire system (MorphoAccess Sigma Wave, MorphoWave
PC Wave, Ethernet switch).
Unplug the USB 3.0 connector of the MorphoWave
Unplug the external power supply of the MorphoWave
Connect to the PC the new MorphoWave
PC port.
Connect its external power supply.
Turn on the whole system.
Once the boot procedure is finished (boot time may take several minutes depending
of the database size) the MorphoWave
identification will work if at least one user is in database.

PC Wave change procedure

To replace the PC on MorphoWave
On the MorphoAccess Sigma Wave, follow the unpairing procedure (step 1 and 2)
to disassociate the sensor.
Turn off the entire system.
Connect the new PC: power supply, USB 3.0 connection with FOTF, Ethernet
connection with Ethernet switch.
Turn on the whole system and follow the pairing procedure.
Once the boot procedure is finished (boot time may take several minutes depending
of the database size) the MorphoWave
identification will work if at least one user is in database.

MorphoAccess Sigma Wave change procedure

To replace the MorphoAccess Sigma Wave on MorphoWave
On the PC follow steps 1, 4 & 5 of the unpairing procedure.
Delete "Pair_Certificate.data" in explorer window.
Turn off the entire system.
Connect the new MorphoAcess Sigma Wave reference: power supply, Ethernet
connection with Ethernet switch.
Turn on the system.
Once the boot procedure is finished, follow MorphoAccess Sigma Wave installation
procedure. One enrolment has to be performed prior to get the MorphoWave
Desktop sensor turned on.
This document and the information therein are the property of Morpho.
84
They must not be copied or communicated to a third party without the prior written authorization of Morpho
Desktop change procedure
TM
Desktop sensor:
TM
OEM system:
TM
MorphoWave
TM
Desktop connected to the PC.
TM
Desktop.
TM
Desktop sensor on the same USB 3.0
TM
Desktop shall have green lighting on and
TM
Desktop shall have green lighting on and
TM
OEM system:
OEM – Installation guide
Annex 1 : Maintenance
TM
Desktop,
TM
2015_2000009096 V4
May 2017

Advertisement

Table of Contents
loading

Table of Contents