Notice; General Precautions; Areas Containing Combustibles; Ethernet Connection - Safran Morpho MorphoWave OEM Installation Manual

Fingerprint recognition terminal
Table of Contents

Advertisement

Notice

The manufacturer cannot be held responsible in case of non-compliance with the
following recommendations or incorrect use of the terminal.

General precautions

Do not attempt to repair your terminal yourself. The manufacturer cannot be held
responsible for any damage/accident that may result from attempts to repair
components. Any work carried out by non-authorized personnel will invalidate your
warranty.
Do not expose the terminal to extreme temperatures, outdoor conditions,
temperatures exceeding [10°C; 35°C].
Use your terminal with original accessories. Attempts to integrate unapproved
accessories to the terminal will void your warranty.
Due to electrostatic discharge, and depending on the environment, synthetic carpet
should be avoided in areas where the terminal has been installed.

Areas containing combustibles

It is strongly recommended that you do not install your terminal in the vicinity of gas
stations, petroleum processing facilities or any other facility containing flammable or
combustible gasses or materials.

Ethernet connection

It is recommended to use a category 5 shielding cable (120 Ohms). It is also strongly
recommended to insert a repeater unit every 90m.
Extreme care must be taken while connecting Ethernet wire to the terminal block
board since low quality connection may strongly impact Ethernet signal sensibility.
It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do
the same with Tx+/Tx- and the other twisted-pair wire).

Date / Time synchronization

If you want to use the terminal for application requiring high time precision, we
recommend synchronizing regularly your terminal time with an external clock (using
NTP).
The terminal clock has a +/-10 ppm typical time deviation at +25°C (roughly less than
+/- 1 sec per day).
At lower and higher temperature, deviation may be more important.
If date / time is not synchronized, don't forget to change battery after long power cut
or after several short power cut.
This document and the information therein are the property of Morpho.
70
They must not be copied or communicated to a third party without the prior written authorization of Morpho
OEM – Installation guide
TM
MorphoWave
Section 6 :Recommendations
2015_2000009096 V4
May 2017