Morphoaccess Sigma Wave Tamper Switch; Integrator Tamper Switch; Figure 17: Morphoaccess Sigma Wave Tamper Switch Wiring; Figure 18: Integrator Tamper Switch Wiring - Safran Morpho MorphoWave OEM Installation Manual

Fingerprint recognition terminal
Table of Contents

Advertisement

OEM – Installation guide
TM
MorphoWave
Section 3 : Installation Procedure

MorphoAccess Sigma Wave Tamper Switch

Figure 17: MorphoAccess Sigma Wave Tamper switch wiring

3
Switch 1
A
4
Switch 2
Operating principle for the switch
Product installed on the wall plate: switch enabled (contact closed).
Product opened (rear connectors accessible): switch disabled (contact open).
Nominal characteristics of switch block
100 mA at 30 VDC max (Resistive load) according to the safety extra low voltage
standard.
This MorphoWave
customer's responsibility to connect the tamper switch (contact) to
physical access controller, in order to prevent the access to the connector
blocks.

Integrator Tamper Switch

3
Switch 1
C
6
Switch 2
2015_2000009096 V4
May 2017
A
1
6
TM
OEM terminal is part of security system; it is
A
1
6

Figure 18: Integrator Tamper switch wiring

This document and the information therein are the property of Morpho.
They must not be copied or communicated to a third party without the prior written authorization of Morpho
B
C
D
1
1
1
6
6
6
Tamper switch contact
Strip on tamper switch
B
C
D
1
1
1
6
6
6
Integrator
tamper switch
41