Figure 20: Wiegand Output Wiring - Safran Morpho MorphoWave OEM Installation Manual

Fingerprint recognition terminal
Table of Contents

Advertisement

OEM – Installation guide
TM
MorphoWave
Section 3 : Installation Procedure
5
Digital ground
A
6
Digital ground
3
D0_OUT
4
D1_OUT
5
LED1
B
6
LED2
The use of LED1 and LED2 wires is described in the paragraphs below.
The controller supports neither LED1 nor LED2 signals
When the access controller has no relay contact to provide an answer to the
MorphoAccess Sigma Wave terminal, then the decision to emit either the "access
granted" signal or the "access denied" signal is taken by another way. It is either the
MorphoAccess Sigma Wave terminal itself that decide, or it waits for the access
controller answer through the local area network (TCP), or on the serial port in (RS422).
It is strongly recommended to disable the LED IN feature, to avoid any interference on
MorphoAccess Sigma Wave terminal behavior.
The controller supports only LED1 signal
When the access controller has only one relay contact which is dedicated to the "access
granted" answer, this one must be connected between the LED1 and GND wires. The
LED1 wire is set to the low level by closing the contact between the LED1 and the GND
wires, and it means "access granted".
2015_2000009096 V4
May 2017
A
1
6

Figure 20: Wiegand output wiring

This document and the information therein are the property of Morpho.
They must not be copied or communicated to a third party without the prior written authorization of Morpho
B
C
D
1
1
1
6
6
6
Ground for Wiegand (connect pin 5 or 6)
Ground for Wiegand (connect pin 5 or 6)
Out Wiegand OUT D0 (5V TTL)
Out Wiegand OUT D1 (5V TTL)
Wiegand LED IN 1 (option) : panel
feedback
In
(Output type required: Open drain or
5V+/-5%)
Wiegand LED IN 2 (option) : panel
feedback
In
(Output type required: Open drain or
5V+/-5%)