MorphoAccess
J Series – Installation Guide
1. Installation directly on a wall
Required tools (not supplied)
Equipment from the initial package to use
Step by step procedure
DOCUMENT SSE-0000077503-04 - M
M
D
- R
ORPHO
OCUMENT
EPRODUCTION AND DISCLOSURE PROHIBITED
•
One (1) Philips head screw driver
•
One (1) Drill (with a Ø 5mm drill bit)
•
One (1) Hole saw Ø 67mm
•
One (1) Flat tip screw driver (diameter 2,5mm) for block connectors screws
•
One (1) Terminal's body
•
One (1) Smoked front cover
•
Two (2) Block connectors
•
Two (2) M3X25 screws
•
Two (2) rawplugs (for Ø 3mm screws)
•
Two (2) M2.5X14 screws
•
Two (2) Screw rubber caps
•
One (1) L-shaped Torx screw driver
Power supply from electrical source shall be switched off before starting the
installation.
1. If not present, drill in the wall a hole with a diameter of 67mm (see
Figure 3.1).
2. Confirm the presence inside the hole of all the cables needed for the
electrical installation (see Section 4).
3. Drill in the wall 2 holes with a diameter of 5mm and fit them with the
rawplugs (see Figures 3.1 and 3.2).
2011
ARCH
Section 3: Installation procedure
17