OEM – Installation guide
TM
MorphoWave
Section 3 : Installation Procedure
Connecting MorphoAccess Sigma Wave terminal with default Ethernet
configuration
Administrator must change the default Ethernet configuration before deploying
terminal on site. This can be achieved by several ways as mention below.
 Terminal LCD Menu > Communication Menu > Network Interface > Ethernet
 MBTB > Quick Configuration > Communication Configuration > IPv4 Address
Settings
 Webserver > Terminal Settings > Communication > IPv4 Network
Prior to connecting through MBTB or Webserver, please check if Terminal is accessible
from Host system/PC or not. To access terminal which is having default network
parameter, the administrator may need to modify the network parameters of the Host
PC.
Please refer to following example to connect terminal which is having default network
parameter.
Figure 27: Direct Point to Point Ethernet Connection
1. Connect terminal directly to PC with Point to Point Ethernet connection.
2. Change the Host PC IP address to 192.168.1.11 (or any IP address within
192.168.x.x range excluding 192.168.1.10)
3. Connect terminal with its default IP address i.e. 192.168.1.10 either from MBTB
or Webserver.
4. Change the Terminal network parameter from MBTB or Webserver.
NOTE: For connecting terminal directly to a PC (Point to Point connection) by an
Ethernet cable, the Ethernet port of the PC must support the Auto-MDIX feature,
otherwise a crossover Ethernet cable is mandatory. If no crossover Ethernet cable
is available, then a dedicated switch can be used for the connection.
Recommendations for RJ45 wiring
Pin
Signals
2015_2000009096 V4
May 2017
1
2
3
Data
Data
Data
pair 1
pair 1
pair 2
This document and the information therein are the property of Morpho.
They must not be copied or communicated to a third party without the prior written authorization of Morpho
4
5
NC/POE pin
NC/POE pin
dedicated (+)
dedicated (+)
6
7
8
Data
Ground/ pin
NC/POE pin
dedicated (-)
dedicated (-)
pair 2