5.7.2 MODE OF OPERATION

Recipe display
When the spray gun is connected to the control unit and the
control unit is switched on, the pre-defined recipe (R1, R2 or R3) is
shown on the gun display (2) as follows.
Recipe 1
Recipe 2
Recipe 3
Recipe change R1
R2
Press the operating button (4) and hold the button pressed for at
least 2 seconds to go forward 1 recipe.
Display (2)
If the operating key (4) is pressed for 2 seconds, the saved recipe values for the previously selected recipes
numbers will be reloaded from the memory.
Status display during spraying mode
During spraying mode (trigger lever pressed), the status is shown in the display (2) by LEDs.
LED display
LEDs 1 - 3 light up green
One or both right-hand LEDs illuminate in
orange.
(Warning display: You can continue working
without any limitations.)
ORDER NUMBER DOC 2366717
R3
R1
= Recipe values changed temporarily:
Description
The spray gun is working in an optimal
high-voltage spray current range.
Spray current too high.
Possible causes:
2
- Spray gun too close to the work piece
- Contamination of the spray gun
R2
3
4
B_03182
39