Setting The High Voltage - WAGNER AquaCoat 5010 GM 5020EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 02/2018
OPERATING MANUAL

7.4.9 SETTING THE HIGH VOLTAGE

80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
8
7
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
7
21
Above the "High-voltage" button (7) is the "High-voltage" bar graph display (21). If the
control unit is in the ready position, this light strip shows the set value as a dot.
ORDER NUMBER DOC 2366717
Procedure
1. Press the "High-voltage" button (7)
to adjust the high voltage.
The LED (8) indicates that high voltage
is selected.
POWER
POWER
0
1
AquaCoat
B_03375
27
2. The high voltage can now be adjusted
using the universal rotary controller (2)
between 5 to 70 kV with a resolution
of 1 kV. The corresponding value is
indicated in the LED display (27).
POWER
POWER
0
1
AquaCoat
B_03376
2
61