7.5.2 ACCESS TO THE DEVICE CONFIGURATION MODE

80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
4
3
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
8
6
4
ORDER NUMBER DOC 2366717
Procedure
POWER
POWER
0
1
AquaCoat
B_03381
25
27
POWER
POWER
0
1
AquaCoat
B_03507
2
27
POWER
POWER
0
1
AquaCoat
B_03508
1. Switch device to "Standby" by
pressing the "Standby" key (3).
The "Standby" LED (4) lights up
yellow.
2. Press and hold the "Service" push
button (25).
3. Turn the universal control dial (2)
with the other hand until the LED
display (27) shows the number "10".
Then release the "Service" button (25).
The running text "configuration" is
displayed in the LED display (27).
The device is now in configuration
mode.
4. The first configuration parameter C11
is now displayed in the LED display (27).
The two LED displays "Spray current"
(6) and "High voltage" (8) flash at the
same time.
The "Standby" (4) LED display flashes
quickly.
Note:
The C11 parameter can be changed,
but this will not have any effect.