Spraying - WAGNER AquaCoat 5010 GM 5020EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 02/2018
OPERATING MANUAL

7.4.3 SPRAYING

1. Insert the desired nozzle into the spray gun.
2. Commissioning the system
3. Open air regulator at the rear of the gun.
4. Spray on a test object (pull trigger).
5. – DD10 pump:
Use the pump pressure regulator (9) and atomizing air regulator (11) to set the
spray pressure to a point at which optimal product atomization is achieved.
– DD10-/ZIP52 pump with product pressure regulator:
Use the product pressure regulator (10) and atomizing air regulator (11) to set the
spray pressure to a point at which optimal product atomization is achieved.
Rule of thumb: Set atomizing air pressure approx. three times higher than the product
pressure.
Round-jet method
6. Open air regulation.
7. Changing the EAWRV 5000 spray jet width: Switch off high voltage. Turning the union
nut in accordance with Chapter 7.4.1.
Flat-jet method: Changing the spray jet width
8. Change the width of the spray jet by turning the air regulator (at the rear of the spray gun,
see illustration) or by appropriate selection of the nozzle.
Air regulation closed.
Flow rate
9. Flow rate may be able to be reduced by:
– Minimizing the product pressure.
– Use a different nozzle size.
For discharge quantity measurements see
– Limit the valve needle stroke with the adjustment screw on the side of the gun.
ORDER NUMBER DOC 2366717
see Chapter 7.4.2.
Air regulation fully opened.
B_04783
Chapters 13.2.3
Round-jet method
Open air regulation.
Flat-jet method
(round jet)
and13.3.3
(flat jet).