8.2.4 CHANGING THE SPRAY GUN WITH HOSE SET

Example
for ZIP52
6
7
Disassembly
1. Dismount the VM 5020W control unit in accordance with Chapter 10.5.
2. Rear of the control unit: Loosen the knurled nut on the gun cable (5) and
remove plug.
3. Loosen the union nut (4) of the air hose at the AquaCoat cabinet.
4. Loosen the union nut (6) on the bared part of the product hose (7).
5. Unscrew knurled nut (2).
6. Carefully remove the gun (1) together with the hose set.
Assembly
The GM 5020EAW spray gun can be combined with different hose sets.
The available hose sets are listed in the accessories (Chapter 13.4).
1. Push bared part of product hose approx. 1.25 m; 4.1 ft through the opening
as far as the mounting plate.
2. Fasten mounting plate (3) to grounding screw with knurled nut (2).
3. Screw bared end of product hose (7) with union nut (6) to pump output
and/or product pressure regulator.
4. Screw air hose (4) to the AquaCoat cabinet.
5. Remove protective sleeve (10), insert gun cable (5) through the bushing
(8), place protective sleeve (10) again. Connect gun cable (5) to control
unit (gun connection (9)). Secure with knurled nut. Push protective
sleeve (10) over the knurled nut and gently fasten using screw (11).
Attach strain relief grommet (8).
6. Fasten the hose set using hose holder (12).
7. Carefully push the VM 5020W control unit back again to the limit stop.
Note the connecting lines and connecting cables at the back of the
control unit!
8. Screw the VM 5020W control unit on the cabinet.
ORDER NUMBER DOC 2366717
1
12
B_05906
8
4
5
3 2
11 10
Ne tze ing an g
Ma in po we r
5
Pis tole
Gu n
Pri m. 1A T
Span nung :
Volta ge:
max. 20Vp p
Strom :
Curre nt:
max. 1,0A
9