Assembly And Installation; Assembling The Aquacoat System - WAGNER AquaCoat 5010 GM 5020EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 02/2018
OPERATING MANUAL
6.4

ASSEMBLY AND INSTALLATION

Check the individual components of the AquaCoat spraying system against the
consignment note. Familiarize yourself with the mode of functioning of the individual
components, reading the enclosed operating manuals thoroughly. Note the special
requirements of the designated electrostatic air spray procedure.

6.4.1 ASSEMBLING THE AQUACOAT SYSTEM

Accessories (option)
1. – Mount underframe with rolls, according to the assembly manual 2367143.
– Mount hose holder in accordance with Chapter 14.5.4).
– Mount gun holder (see Chapter 14.5.5).
– Place tub insert into AquaCoat cabinet.
Pump set
All required parts are included in the scope of delivery of the pump set (see Chapter 14.3).
The cabinet contains two air hoses:
– The air hose 10 mm; 0.39 inch is connected with the control unit, pump air connection.
– The air hose
8 mm; 0.32 inches is connected with the control unit, product pressure
regulator connection.
Procedure:
2. Screw the pump to pump support (see Chapter 14.3).
3. Screw the orange potential equalization line (see Chapter 5.1) to pump's grounding
connection. (Grounding connection see pump's operating manual.)
4. Mount suction hose on pump inlet.
5. Pump's air supply: Connect air hose
compressed air inlet.
6. DD10-/ZIP52 pump with product pressure regulator: Connect air hose
(see Chapter 5.1) to product pressure regulator.
Hose set
7. Dismount the VM 5020W control unit in accordance with Chapter 10.5.
8. Mount hose set on the cabinet in accordance with Chapter
ORDER NUMBER DOC 2366717
10 mm; 0.39 inches (see Chapter 5.1) to pump's
8 mm; 0.32 inches
8.2.4
(assembly).
44

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020 gm 5020eaw