WAGNER AquaCoat 5010 GM 5020EAW Operating Manual page 45

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 02/2018
OPERATING MANUAL
Secure cables and hoses
9. Secure al cables and hoses with cable ties in the AquaCoat cabinet.
The door switch moves up and down on the RH cabinet wall. It must
be ensured that no cables and hoses are located within the travel
of the door switch.
Spray gun
10. Mount product hose, air hose and gun cable to spray gun.
SW19
2.5 Nm
Order No.
2 *
9992698
* Use Vaseline sparingly
Control unit
11. Carefully push the VM 5020W control unit back again to the limit stop. Note the
connecting lines and connecting cables at the back of the control unit!
12. Screw the VM 5020W control unit on the cabinet.
Additional Accessories (option)
13. Mount additional Accessories, if available.
ORDER NUMBER DOC 2366717
SW19
2.5 Nm
2
B_05983
Description
Vaseline white, PHHV II
SW19
Air hose
When screwing on the air hose, a
second open-ended/ring spanner
must be used for bracing.
B_05954
Gun cable
45