OPERATING MANUAL
Trigger functions
The trigger can be used to activate, one after the other, the various
functions of the spray gun.
Distance
Description
1
Atomizing air open.
2
Atomizing air open and electrostatically
(high voltage) activated.
Display (2) for "spray current" on the spray gun
3
Atomizing air open, electrostatically
(high voltage) activated and product valve open.
4
Overall way of trigger.
- An increase in the force needed to pull the trigger back will be
perceived at the position where the product valve opens.
- For spraying without high voltage, the high voltage can be
switched off using the operating button (4). Press the operating
button (4) briefly: High voltage is switched off. The standby
display (3) illuminates.
- In the event of a malfunction the spray gun switches to
"standby" operating mode and the display (3) illuminates.
- The relationship between shaping air and atomizing air is set
using the air regulator (16).
ORDER NUMBER DOC 2366717