WAGNER AquaCoat 5010 GM 5020EAW Operating Manual page 65

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 02/2018
OPERATING MANUAL
Review counter status since last service carried out on gun
22
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
18
17
6
5
7.4.13.2 "CARRY OUT SERVICE" DISPLAY
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
ORDER NUMBER DOC 2366717
Procedure
27
1. Press the "Service" button (25) to
access the service menu. LED (26)
lights up.
2. Actuate the push button R2 (17) for a
short time; the LED (18) display lights
up.
3. Read off display in the LED display
(27). In the example, 46 hours have
POWER
POWER
0
1
passed since realization of the last
spray gun service. The bar display to
the left (22) indicates that 50% of the
AquaCoat
set interval time has passed.
B_03384
4. By keeping push button (5) pressed
2
down, the display in the LED display
(27) can be set to "0" (reset after
expiry of the set interval limit).
Prerequisite
The "Service interval limit" function is
activated (see Chapter 7.4.13.1).
"Service spray gun"
Once the time for the defined maintenance
interval has expired, the LED display (26)
starts to flash.
The flashing service display merely acts
POWER
POWER
0
1
as a warning. You can continue working
without any limitations.
AquaCoat
B_03385
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020 gm 5020eaw

Table of Contents