Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 02/2018
OPERATING MANUAL
B_04371
7
B_04798
1
8
SW14
Two gold contact sleeves either
remain in the handle (1) or are
seated on the two gold pins (2).
Do not lose!
ORDER NUMBER DOC 2366717
10
5
4
1
SW5
3
2
2
1. Loosen the oval head screw (3).
2. Pull the air valve (4) out off the drilled hole. Do not turn!
3. Only as required:
1. Remove pressure spring (4).
2. Loosen clamping screw (1) with
assembly tool (5).
3. Unscrew valve rod unit (2, 6, 7).
The packing (3) is also unscrewed
and removed.
4. Only as required:
Remove rod seal (10). Do not damage
the housing in the process.
SW6
SW2
6 7
9
4
SW5
Torx® 20
3
Do not damage the cylindrical surfaces. Ideally press
on the tappet from behind using a transversely held
screwdriver, for example.
Press out seal (5) using a handle seal assembly tool
(Order No. 2342334, not included in scope of delivery)
5
B_04799