TECHNICAL DATA

5.5.1 AQUACOAT 5010/5020 ENTIRE SYSTEM

Description
Compressed air Inlet
Air pressure quality:
free from oil and water
Air inlet connection
Ambient temperature
Relative humidity
Maximum product temperature
Product pH value
Product viscosity
Allowable inclination for operation
Sound pressure level
Weight (without product tank and pump)
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water.
ORDER NUMBER DOC 2366717
Values
0.4–0.8 MPa
4–8 bar
58–116 psi
Quality standard 6.5.2 according to ISO 8573.1, 2010
6: Particle density ≤ 5 mg/m3
5: Humidity: pressure dew point ≤ +7 °C
2: Oil content ≤ 0.1 mg/m3
R 1/2" I
Operation
5...40 °C; 41...104 °F
Assembly
0...40 °C; 32...104 °F
Suspension
-20...60 °C; -4...140 °F
10–95% (without condensation)
50 °C; 122 °F
3.5–9
see Chapter
±10
When the cabinet is open:
Depending upon the product pressure generator,
information can be found in the corresponding
operating manual.
When the cabinet is closed:
The values are 10–12 dB(A) lower.
AquaCoat 5010: 62 kg; 136.7 lb
AquaCoat 5020: 70 kg; 154.3 lb