Nominal flow rate
Nominal flow rate 0.6 m³/h, length 110 mm, nominal
pressure PN16, connection G ¾ B
Nominal flow rate 0.6 m³/h, length 190 mm, nominal
pressure PN16, connection G 1 B
Nominal flow rate 1.5 m³/h, length 110 mm, nominal
pressure PN16, connection G ¾ B
Nominal flow rate 1.5 m³/h, length 110 mm, nominal
pressure PN25, connection G ¾ B
Nominal flow rate 1.5 m³/h, length 190 mm, nominal
pressure PN16, connection G 1 B
Nominal flow rate 2.5 m³/h, length 130 mm, nominal
pressure PN16, connection G 1 B
Nominal flow rate 2.5 m³/h, length 190 mm, nominal
pressure PN16, connection G 1 B
Type of meter and mounting location
Mounting place cold side, temperature sensor cold
side directly integrated into the volume measurement
unit
Mounting place hot side, temperature sensor hot side
directly integrated into the volume measurement unit
Temperature sensor type
Temperature sensor Pt500, not removable, directly in
water, type DS, M10x1 / immersion length 27.5 mm,
cable length 1.5 m
Temperature sensor Pt500, not removable, directly in
water, type DS, M10x1 / immersion length 27.5 mm,
cable length 5 m
Temperature sensor Pt500, not removable, directly in
water or for protection pocket, Ø5.2x45 mm, cable
length 1.5 m
Temperature sensor Pt500, not removable, directly in
water or for protection pocket, Ø5.2x45 mm, cable
length 5 m
Control cable / type / electronic unit
Split version with 1 m control cable
Power supply
Battery for 11 years (C-cell)
Standard battery for 6 years (2xAA cells)
Power supply 24 V AC / DC with connecting terminals
Communication
Without communication interface
With pulse output
With M-Bus
Manufacturer's label
Logo Landis+Gyr
Other labels on request
County / where used
Dial plate for Austria (German)
Dial plate for Bulgaria (Bulgarian)
Code
Dial plate for Switzerland (German/French)
05
Dial plate for China (Chinese)
Dial plate for Czech Republic (Czech)
07
Dial plate for Germany (German)
Dial plate for Denmark (Danish)
21
Dial plate English neutral
Dial plate for Croatia (Croatian)
22
Dial plate for Hungary (Hungarian)
Dial plate for Iceland (Icelandic)
23
Dial plate for Italy (Italian)
Dial plate for Japan (Japanese)
36
Dial plate for Luxembourg (German/French)
Dial plate for Mongolia (Mongolian)
38
Dial plate for the Netherlands (Dutch)
Code
Dial plate for Poland (Polish)
Dial plate for Romania (Romanian)
1
Dial plate for Sweden (Swedish)
Dial plate for Slovak Republic (Slovakian)
Dial plate for Ukraine (Ukrainian)
4
Dial plate for Belgium (French/Flemish)
Code
Dial plate for Kazakhstan (Russian)
Dial plate for Belarus (Russian)
7B
Dial plate for Bosnia-Herzegovina (Croatian)
Dial plate for Lithuania (English)
Dial plate for Slovenia (Slovenian)
7C
Dial plate for Armenia (Armenian)
Dial plate for Russia (Russian)
Dial plate for Uzbekistan (Russian)
7H
Dial plate for France (French)
Dial plate for Middle East (English)
Dial plate for Australia (English)
7J
Dial plate for Moldova (Rumanian)
Dial plate for Spain (Spanish)
Code
Dial plate for Serbia (Serbian)
B
Energy unit
Code
Display: kWh
3
Display: MWh with 3 decimal places
7
Display: MJ
K
Display: GJ with 3 decimal places
Code
Calibration / conformity
0
Tested according to EN 1434, class 3, with lock mark
1
Compliant with EN 1434, class 3 *)
5
Tested according to EN 1434, class 2, with lock mark
Code
Compliant to MID class 2
00
Compliant to MID class 3
xx
*) Calibrated devices are offered accordingly to the
Code
current approvals.
18/21
D
L
B
P
G
A
F
T
K
J
M
Q
W
V
S
E
H
R
C
U
N
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Z*
Code
A
B
C
D
Code
2
3
4
S
R