4. Gently lift and remove the DIMM from the slot.
5. Install the DIMM in the order of DIMM population sequence (see the
population
sequence). Align the golden key of the DIMM with the receptive point on
the slot.
6. Insert and gently press down the DIMM into the slot until the retaining clips snap into
the locked positon.
NOTE:
Make sure that retaining clips engage the notches on the DIMM. If the
retaining clips are not in the fully-closed position, the DIMM has not been correctly
installed. Press the DIMM firmly into the slot again until the retaining clips are fully
seated.
DIMM slot layout:
DIMM population sequence:
The white slots take the priority, while CPU1 DIMM shall be symmetrically installed
with CPU0 DIMM.
For the single CPU, the DIMM population follows the screen printed sequence: CPU0_
C0D0, CPU0_C1D0, CPU0_C2D0, CPU0_C3D0, CPU0_C4D0, CPU0_C5D0; CPU0_C0D1,
CPU0_C3D1.