Inspur Server User Manual
OB5161M5

Advertisement

Table of Contents
loading

Summary of Contents for Inspur OB5161M5

  • Page 1 Inspur Server User Manual OB5161M5...
  • Page 2 Inspur. The information in this manual is subject to change without notice. Inspur is the registered trademark of Inspur. All the other trademarks or registered trademarks mentioned in this manual are the property of their respective holders.
  • Page 3: Target Audience

    4.Please install the product-compatible operating system and use the driver provided by Inspur. If you use an incompati ble operating system or non-Inspur driver, it may cause compatibility issues and affect the normal use of the product, Inspur will not assume any responsibility or liab ility.
  • Page 4: Table Of Contents

    Contents 1 Safety Instructions ......................... 1 2 Product Specification ........................6 2.1 Introduction ..........................6 2.2 Product Specifications ........................ 6 2.3 Motherboard Components......................7 2.4 Motherboard Topology Diagram ....................9 3 Hardware system ........................... 8 3.1 Product View ..........................8 3.2 Install the server into the rack ....................
  • Page 5 5.3 Web Module ..........................80 5.4 Storage ............................85 5.5 Remote Control .......................... 85 5.6 Fan .............................. 87 5.7 BMC Settings ..........................87 5.8 Logs ............................91 5.9 Fault Diagnosis..........................93 5.10 System Maintenance ........................ 95 5.11 Service & Protocol ........................98 5.12 User Management ........................
  • Page 6: Safety Instructions

    For your safety, please do not attempt to remove the cover of the system to remove or replace any component without assistance provided by Inspur. Only service technicians trained by Inspur are authorized to remove the cover of the host, and to remove and replace internal components.
  • Page 7 fire or electric shock. Please place the system far away from the cooling plate and heat sources, and be sure not to block the air vents. Please be sure not to scatter food or liquid in the system or on other components, and do not use the product in humid or dusty environments.
  • Page 8 Please remember that only service technicians trained by Inspur are authorized to remove the cover of the host, and to remove and replace internal components.
  • Page 9 Upon receiving the proper authorization from Inspur and dismounting the internal components, please pay attention to the following: Switch the system power supply off and disconnect the cables, including all connections of the system.
  • Page 10 Safety Introduction be careful; as the sliding may hurt your fingers. Do not overload the AC power supply branch circuits in the rack. The total load of the rack should not exceed 80% of the ratings of the branch circuits. Ensure that components in the rack have good ventilation conditions.
  • Page 11: Product Specification

    Under the demand and support of overseas business, at the CeBIT 2017 in Hannover, Inspur, as the first members of Open19 project, released the first batch of servers based on the Open19 standard when the Open19 project was only established for 9 months.
  • Page 12: Motherboard Components

    Product Specification Management  IPMI 2.0 compliant with AST 2500  Front: Power button with LED, UID button with LED, Indicator Light SYSTEM_ERROR LED, and HDD_ERRER LED Support TPM 2.0  Operating environment temperature 0 ℃ -40 ℃  Storage and transport temperature -40 ℃...
  • Page 13 VGA connector Power board connector JBOD connector VPP signal connector RJ45 connector BP I2C connector CLR_CMOS BP I2C connector Front board connector Front board connector SSATA2-5 connector TPM connector SATA0-3 connector PSU1 OCPC connector PSU0 OCPA connector FAN 0 CPLD JTAG connector FAN 1 BMC debug connector FAN 2...
  • Page 14: Motherboard Topology Diagram

    Product Specification Product Specification 2.4 Motherboard Topology Diagram 2.4 Motherboard Topology Diagram DDR IV DIMM DDR IV DIMM DDR IV DIMM DDR IV DIMM UPI0 UPI0 Skylake DDR IV DIMM DDR IV DIMM Skylake CPU1 UPI1 UPI1 CPU0 DDR IV DIMM DDR IV DIMM DDR IV DIMM DDR IV DIMM...
  • Page 15: Hardware System

    3 Hardware system 3 Hardware system 3.1 Product View 3.1 Product View Front View Front View Item Name Function Item Name Function VGA connector VGA connector USB 2.0 connector USB 2.0 connector 1. On (Red): Any of HDD0~HDD11 attached to HBA/Raid Card have error. 1.
  • Page 16: Install The Server Into The Rack

    Hardware system Hardware system 3.2 Install the server into the rack 3.2 Install the server into the rack Rack prepare Rack prepare Before installing the servers into the rack, the rack must be fixed tightly and be grounded Before installing the servers into the rack, the rack must be fixed tightly and be grounded well.
  • Page 17: Start The Server

    Fixed the server by tightening the screws on the both sides.  3.3 Start the server CAUTION: Before starting the server, make sure that you have read and followed the contents of Safety Instructions in this manual. Once you have started the server, it is considered that you have read the contents of Safety Instructionsin this manual.
  • Page 18: Bios Setup

    4.1 Login to the BIOS Interface Power up the server, the system starts to boot, when the screen shows the following Inspur Logo prompt: When pressing <DEL> to SETUP or <TAB> to POST or <F11> to Boot Menu or <F12> to PXE Boot as shown in the following figure, press the [DEL] key, the system will show “Entering...
  • Page 19 Press “TAB” key to display the POST process system information.  Press “F11” key to enter the startup management interface and select the startup device  to start. Press the “F12” key to start the network PXE pre-boot environment.  Description Table of BIOS Setup Interface Control Key Features <Esc>...
  • Page 20: Uefi/Legacy Mode Switching

    BIOS Setup 4.2 UEFI/Legacy Mode Switching Log in to the BIOS Setup interface, select the “Advanced  CSM Configuration” interface, press Enter, set the Boot Mode option, set the system startup mode (UEFI Mode/Legacy Mode), and set the implementation method of Option ROM of Network, Storage, Video Oprom Policy and other PCI devices accordingly as shown in the following figure.
  • Page 21: Viewing Cpu Details

    of current system, including BIOS, BMC and ME version information, CPU, PCH SKU, RC version, memory etc. as shown in the following figure. 4.4 Viewing CPU Details Log in to the BIOS interface, select “Processor  Processor Configuration  Processor Information”, press Enter to display CPU details as shown in the following figure.
  • Page 22: Viewing Memory Information

    BIOS Setup 4.5 Viewing Memory Information Log in to the BIOS interface, select “Processor  Memory Configuration  Memory Topology”, press Enter to display manufacturer, rate, and capacity information of the in- position memory as shown in the following figure. 4.6 View Hard Drive Information and RAID Configuration 4.6.1 View Hard Drive Information Log in to the BIOS and select “Chipset ...
  • Page 23 3.Press Enter to enter, and then executable operation and current hard drive information will be displayed as shown in the following figure. 4.Create a RAID volume. Select “Create RAID Volume” option and press Enter to enter as shown in the following figure, please refer to the specific operation.
  • Page 24 BIOS Setup Description Table of Create RAID Menu Operation Interface parameter Function Description Please enter volume label names with the length of less than 16 characters but Name without special characters at the end. Please select the RAID volume level. If you have not created a volume yet, there are four volume levels: RAID0 (Stripe), RAID1 (Mirror), RAID10 (RAID0+1) and RAID5 (Parity).
  • Page 25 6.When the Boot Mode is set to Legacy mode, during the system startup process, the screen...
  • Page 26 BIOS Setup will prompt: Press <CTRL-I> to enter Configuration Utility…, press <Ctrl> and <I> to enter the SATA RAID configuration interface, and the actual figure is shown in the following. 7.Enter the SATA RAID configuration interface as shown in the following figure, the system will show menu list information, hard drive information connected to the SATA controller (hard drive ID No., hard drive model, hard drive capacity and whether the hard drive is a volume member, etc.), existing RAID volume Information (including volume ID No., name,...
  • Page 27 Description Table of Operating Menu Create RAID Volume Create a RAID volume Delete RAID Volume Delete existing RAID volumes. Reset Disks to Non-RAID Reset the hard drive in the RAID volume to restore it to a non-RAID status. Mark the hard drive as spare mode. As a spare hard drive, the data will be Mask Disk as Spare cleared and cannot be selected when RAID is set.
  • Page 28 BIOS Setup After the above settings are completed, please select [Create Volume] and press Enter key, and then the system prompts: “WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N): “. If you are sure to create a RAID volume, please enter “Y”...
  • Page 29 b)Mask Disk as Spare menu. Enter the Mask Disk as Spare menu as shown in the following figure, the system will display the hard drive without RAID volume. Please use the space bar to select the hard drive as Spare mode and press Enter. The system prompts “Are you sure you want to Mask selected disks as Spare? (Y/N)”, type “Y”...
  • Page 30: Viewing And Setting Of Bmc Network Parameter

    BIOS Setup 4.7 Viewing and Setting of BMC Network Parameter 4.7.1 View BMC Network Parameters Log in to the BIOS and choose “Server Mgmt  BMC Network Configuration  BMC IPv4 Network Configuration/BMC IPv6 Network Configuration”, Press Enter to view the configuration of the current BMC IPv4 and BMC IPv6 network parameters as shown in the following figure.
  • Page 31 4.7.2 BMC Network Settings Take the BMC shared interface as an example to describe the settings of the BMC IPv4 network parameters. The specific parameter settings are shown in the table.
  • Page 32 BIOS Setup Description Table of BMC Network Configuration Interface Interface parameter Function Description Defaults Get the mode setting of the BMC management network port parameters. The option parameters are: Get BMC Sharelink/Dedicated Do Nothing: Do not operate. Do Nothing Parameters Auto: Automatically obtain the current BMC network settings.
  • Page 33 confirm as shown in the following figure: After the setting is successful, it will prompt: “Set Static BMC Station IP OK!!!”, press Enter to confirm, the BMC network IP will take effect immediately. When setting fails, it will prompt: “Set Static BMC Station IP Fail!!!”, If the setting IP is not changed, it will prompt: “Static BMC Station IP Not Change!!!”.
  • Page 34 BIOS Setup 2.Set BMC Dynamic Network Parameters Set the Configuration Address source option to [DynamiBmcDhcp] from [Static]. After the setting is successful, it will show the prompt: “Set Dynamic BMC IP Address Source Success! Dynamic BMC Network Parameters are Getting Now, Please Wait a Moment!” as shown in the following figure.
  • Page 35 Note: Whenever possible, use the Manual manual setting option to ensure that the network cable of the BMC management port is connected. The option that takes effect immediately in the BIOS Setup interface is implemented by calling the Callback function. The Callback function is called only when the option in the BIOS Setup interface changes, otherwise the function will not take effect.
  • Page 36: Bios Parameter Description

    BIOS Setup 4.8 BIOS Parameter Description 4.8.1 Main The Main interface contains basic information about the BIOS system, such as BIOS, BMC and ME version information, CPU model information, total memory capacity information and system time. The specific parameters are shown in the table, and the Main interface is shown in the figure.
  • Page 37 Description Table of Main Interface Interface parameter Function Description Product Name Product name Serial Number Serial Number Customer ID Customer ID BIOS Version BIOS version Build Date Build date BMC Firmware Version BMC FW version ME Firmware Version ME FW version Access Level Current access level CPU Information...
  • Page 38 BIOS Setup 4.8.2 Advanced The Advanced interface contains parameters for the BIOS system and related function controls, such as ACPI, serial port, PCI subsystem, CSM, USB, onboard network card, etc. The specific parameters are shown in the table, and the Advanced interface is shown in the figure. Description Table of Advanced Interface Interface parameter Function Description...
  • Page 39 Description Table of Trusted Computing Interface Interface parameter Function Description Defaults The security device supports the switch settings. Option parameters are: Enabled: Enabled Security Device Disabled: Disabled Enabled Support The BIOS supports TPM TCG version 1.2/2.0. The BIOS supports the TPM module through the TPM software binding.
  • Page 40 BIOS Setup Description Table of Super IO Configuration Interface Interface parameter Function Description Serial port 0 configuration settings, the configuration page provides the switch control and resource adjustment control function of the serial port. Serial Port 0 Configuration The resource adjustment will enable to manually adjust the IO PORT and IRQ number used by COM PORT.
  • Page 41 Description Table of Serial Port 0 Configuration Interface Interface parameter Function Description Defaults Serial port 0 switch settings, option parameters are: Serial Port Enabled: Enabled Enabled Disabled: Disabled Select the optimal settings for the serial port based on your needs. The option parameters are: Auto Changer Settings...
  • Page 42 BIOS Setup Description Table of Console Redirection Settings Interface Interface parameter Function Description Defaults Terminal type setting. Option parameters are: ANSI VT100 Terminal Type VT100+ VT-UTF8 ANSI Bit rate setting. Option parameters are: 9600 9600 19200 Bits per second 38400 57600 115200 Serial data bit width setting.
  • Page 43 The VT-UTF8 combination key supports switch settings. Enabled Option parameters are: VT-UTF8 Combo Key Support Enabled: Enabled Disabled: Disabled Recorder mode switch settings. Option parameters are: Disabled Recorder Mode Enabled: Enabled Disabled: Disabled Extended terminal resolution 100 × 31 switch settings. Disabled Option parameters are: Redirection 100×31...
  • Page 44 BIOS Setup Description Table of PCI Subsystem Settings Interface Interface parameter Function Description Defaults Above 4G memory access control switch settings. Option parameters are: Enabled Above 4G Decoding Enabled: Enabled Disabled: Disabled SR-IOV supports switch settings. Option parameters are: Enabled SR-IOV Support Enabled: Enabled Disabled: Disabled...
  • Page 45 Switch settings supported by Ipv6 HTTP boot. Option parameters are: Ipv6 HTTP Support Enabled: Enabled Disabled Disabled: Disabled Wait for pressing ESC to cancel time limit of PXE boot, and the setting PXE boot wait time range is 0~5. Media detect Count Device Detection Times Setting, and its range is 1~50. ⑧...
  • Page 46 BIOS Setup Start mode setting, control device Legacy or UEFI mode startup policy. Option parameters are: Boot Mode Legacy Mode UEFI Mode: UEFI mode Legacy Mode: Legacy Mode The NIC Option Rom execution mode setting, the option parameters are: Network Do not launch: do not launch Legacy Legacy: traditional mode...
  • Page 47 4.8.4 PCH SATA Configuration/PCH sSATA Configuration PCH sSATA Configuration and PCH SATA Configuration interface is used to configure onboard sSATA and SATA ports as shown in the following figure. The PCH SATA Configuration menu is used as an example to introduce the onboard SATA port hard drive configuration, which is similar to the PCH sSATA Configuration interface and will not discuss here again.
  • Page 48: Miscellaneous Configuration

    BIOS Setup Description Table of USB Configuration Interface Interface parameter Function Description Defaults Onboard USB port switch settings, option parameters are: USB N Enabled: Enabled Enabled Disabled: Disabled 4.8.6 Miscellaneous Configuration The Miscellaneous Configuration interface is a miscellaneous common setting item configuration.
  • Page 49: Server Me Configuration

    4.8.7 Server ME Configuration The Server ME Configuration interface is used to set server ME’s information display and related configuration. The specific parameter description is shown in the table, the Server ME Configuration interface is as shown in the following figure. Description Table of Server ME Configuration Interface Defaults Interface parameter...
  • Page 50: Processor

    BIOS Setup 4.8.8 Runtime Error Logging The Runtime Error Logging interface is the system runtime error log setting. The specific parameter description is shown in the table, and Runtime Error Logging interface is shown in the figure. Description Table of Runtime Error Logging Interface Defaults Interface parameter Function Description...
  • Page 51: Processor Configuration

    Description Table of Processor Interface Interface parameter Function Description Processor Configuration Processor configuration Common Configuration Common configuration UPI Configuration UPI configuration Memory Configuration Memory configuration IIO Configuration IIO configuration Advanced Power Management Configuration Advanced power management configuration 4.9.1 Processor Configuration The Processor Configuration interface is the relevant option settings for the processor.
  • Page 52 BIOS Setup Description Table of Processor Configuration Interface Defaults Interface parameter Function Description Processor Information Processor information submenu, processor details ---- Set the number of CPU cores, enter the number of CPU cores to be turned on, and the Help information will display the valid value that Active Cores can be set by this option and maximum physical cores of the CPU based on the current CPU.
  • Page 53 Hardware prefetching switch setting, option parameters are the same as above. Hardware prefetching refers to pre-fetching instructions or data Hardware Prefetcher from memory into the L2 cache before the CPU processes the Enabled instructions or data, thereby reducing the memory read time and helping to eliminate potential bottlenecks and improve the system performance Adjacent cache prefetch switch settings, option parameters are the...
  • Page 54 BIOS Setup Description Table of Common Configuration Interface Defaults Interface parameter Function Description MMIO high base address setting, option parameters are: MMIO High Base MMIO high interval size setting, option parameters are: 256G MMIO High Granularity Size 256G 1024G Numa switch settings, option parameters are: Enabled Numa Enabled: Enabled...
  • Page 55 Description Table of UPI Configuration Interface Interface parameter Function Description Defaults UPI link status submenu showing the current UPI link status ---- UPI Satus Reduce the priority setting, the option parameters are: Topology Precedence Topology Precedence Degrade Feature Precedence Precedence Reduce the feature by setting the Topology Precedence when the system settings conflict, or reduce the Topology by setting the Feature Precedence.
  • Page 56: Memory Configuration

    BIOS Setup Sub NUMA cluster settings, option parameters are: Disabled Auto: Support 1-cluster or 2-clusters based on IMC Sub NUMA interleaving Clustering Enabled: Supports all SNC clusters (2-clusters) and 1-way IMC interleaving Disabled: SNC function is not supported. Legacy VGA Socket The traditional VGA setting, the valid value range is 0~1. The number of traditional VGA stack settings, the valid value Legacy VGA Stack range is 0~6...
  • Page 57: Memory Map

    Data Scrambling for NVMDIMM data scrambling switch setting, option parameters are the Enabled NVMDIMM same as above. DDR4 data scrambling switch settings, option parameters are: Data Scrambling for Auto: Automatic Enabled DDR4 Enabled: Enabled Disabled: Disabled ADR enable switch settings, option parameters are: Enable ADR Enabled: Enabled Enabled...
  • Page 58 BIOS Setup Description Table of Memory Map Interface Interface parameter Function Description Defaults Volatile memory mode settings, option parameters are: Volatile Memory Mode Auto 1LM memory cross-interval setting, option parameters are: 1LM Memory Auto Auto 256B Target, 256B Channel Interleave Granularity 64B Target, 64B Channel IMC Interleaving settings, option parameters are: Auto...
  • Page 59: Iio Configuration

    Description Table of Memory RAS Configuration Interface Interface parameter Function Description Defaults Static virtual lockstep mode switch settings, option parameters are: Static Virtual Lockstep Enabled: Enabled Disabled Mode Disabled: Disabled Mirror mode settings, option parameters are: Disabled Mirror Mode Disabled Mirror Mode 1LM Mirror Mode 2LM Mirror TAD0 mode switch settings, option parameters are:...
  • Page 60 BIOS Setup the table, IIO Configuration interface is shown in the figure Description Table of IIO Configuration Interface Interface parameter Function Description Defaults The Socket N configuration submenu is used to set the Link speed and Max Payload Size of CPU0’s PCIE, ASPM and other settings on Socket N Configuration ---- the device, and display the link status, maximum link, current link...
  • Page 61 4.9.6 Advanced Power Management Configuration The Advanced Power Management Configuration interface is the CPU power management related option setting, the specific parameters are shown in the table, Advanced Power Management Configuration interface is shown in the figure. Description Table of Advanced Power Management Configuration Interface Interface parameter Function Description CPU P State Control...
  • Page 62 BIOS Setup Description Table of CPU P State Control interface Interface parameter Function Description Defaults UncoreFreq Scaling settings, option parameters are: Enabled Enabled UncoreFreq Scaling (UFS) Disabled(Min Frequency) Disabled(MAX Frequency) Custom Uncore frequency setting, setting range is 1300-2300, which will 1300 UncoreFrequency display when UncoreFreq Scaling (UFS) is Custom option.
  • Page 63 Description Table of Hardware PM State Control Interface Interface parameter Function Description Defaults The hardware selects whether the P-States is actively set by the OS, Native and the default value is determined based on the actual test. Option Mode parameters are: Hardware P-States Disabled: Hardware selects P-States based on traditional OS requests Native Mode: Hardware selects P-State based on traditional OS boot...
  • Page 64 BIOS Setup Description Table of CPU C State Control Interface Interface parameter Function Description Defaults Monitor/Mwait supports switch settings, and option parameters are: Monitor/Mwait Enabled: Enabled Disabled Support Disabled: Disabled The independent core C state switch is set, the option parameters are: Autonomous Core Enabled: Enabled Disabled...
  • Page 65 Description Table of Package C State Control Interface Defaults Interface parameter Function Description Package C State settings, option parameters are: C0/C1 state C0/C1 state C2 state Package C State C6(non Retention) state C6(Retention) state No Limit 4.9.6.5 CPU-Advanced PM Tuning The CPU-Advanced PM Tuning interface is the CPU energy-saving performance related option setting, where the Energy Perf BIAS menu is available.
  • Page 66: Sever Mgmt

    BIOS Setup Description Table of Energy Perf BIAS Interface Interface parameter Function Description Defaults Energy-saving performance adjustment settings, option parameters are: OS Controls EPB: OS Controls Energy Saving Performance Power Performance Adjustment OS Controls EPB Tuning BIOS Controls EPB: BIOS Controls Energy Saving Performance Adjustment Energy-saving performance management settings, option parameters are:...
  • Page 67 Description Table of Server Mgmt Interface Interface parameter Function Description Defaults BMC Self Test Status BMC self-test status ---- BMC Firmware Current Board BMC firmware version number ---- Version FRB-2 clock switch settings, option parameters are: FRB-2 Timer Enabled: Enabled Enabled Disabled: Disabled FRB-2 clock timeout setting, option parameters are:...
  • Page 68: Bmc Network Configuration

    BIOS Setup The strategy setting upon OS watchdog clock is timeout, the option parameters are: Do Nothing OS Wtd Timer policy Reset Reset Power Down Power Cycle BMC network BMC network configuration submenu ---- configuration BMC User Settings BMC User Settings Submenu ---- VLAN Configuration VLAN configuration submenu ----...
  • Page 69 4.10.1.1 BMC IPv4 Network Configuration The BMC IPv4 Network Configuration interface is used to configure the BMC IPv4 management network through the BIOS. The specific parameter description is shown in the table, the BMC IPv4 Network Configuration interface is shown in the figure. Description Table of BMC IPv4 Network Configuration Interface Interface parameter Function Description...
  • Page 70 BIOS Setup 4.10.1.2 BMC IPv6 Network Configuration The BMC IPv6 Network Configuration interface is used to configure the BMC IPv6 management network through the BIOS. The specific parameter description is shown in the table. The BMC IPv6 Network Configuration interface is shown in the figure. Description Table of BMC IPv6 Network Configuration Interface Defaults Interface parameter Function Description...
  • Page 71 the figure. Description Table of BMC User Settings Interface Interface parameter Function Description Add User Add user submenu Delete User Delete user submenu Change User Settings Modify user settings submenu 4.10.2.1 Add User operation The Add User interface is used to add BMC user through the BIOS. After the addition is completed, it will take effect immediately, and then user will be added to the BMC user list.
  • Page 72: Delete User

    BIOS Setup Description Table of Add User Interface Defaults Interface parameter Function Description ---- User Name User name setting, up to 16 characters. User password setting, password characters must contain at least 8 ---- User Password characters and a maximum of 20 characters including uppercase and lowercase letters, special characters and numbers.
  • Page 73 Description Table of Delete User Interface Interface parameter Function Description User Name Enter the name of the user you want to delete If you want to delete the user password, please enter the password correctly, and then “User User Password Deleted!!!”...
  • Page 74: Vlan Configuration

    BIOS Setup Description Table of Change User Settings Interface Interface parameter Function Description Defaults User Name Enter the user name to be modified ---- Enter the user password to be modified. Only the name and password User Password ---- are entered correctly the following options can be modified. User permission switch settings, option parameters are: User Enabled: Enabled...
  • Page 75: View Fru Information

    Description Table of VLAN Configuration Interface Interface parameter Function Description Defaults BMC shared port/private port VLAN control switch settings, and option parameters are: Sharelink/Dedicated Enabled: Enabled Disabled VLAN Control Disabled: Disabled If VLAN is enabled, you need to set the VLAN ID to set the VLAN to be available.
  • Page 76: Security

    BIOS Setup 4.11 Security The Security interface is used by administrator and user to set password. The specific parameters are shown in the table, Security interface is shown in the figure. Description Table of Security Interface Interface parameter Function Description Defaults Create an administrator password.
  • Page 77: Firmware Update

    Description Table of Boot Configuration Interface Interface parameter Function Description Defaults Setup prompts the timeout setting and sets the time to wait for the Setup Prompt Timeout Setup activation key with the maximum value of 65535 seconds. During the boot process, you can set keyboard Numlock indicator status switch, and option parameters are: BootupNumLock State On: On...
  • Page 78: Firmware Update

    Boot options override, you can select the boot items listed below 4.14 Firmware Update BIOS upgrade version, you can choose to update under UEFIshell or OS. 4.14.1 Upgrade BIOS under UEFI Shell Inspur Logo appears during system startup and the prompt “Press <DEL> to SETUP or...
  • Page 79 <TAB> to POST or <F11> to Boot Menu or <F12> to PXE Boot.” is displayed at the bottom. Press F11 to start the Boot Menu as shown in the following figure, select it by pressing the up and down keys and press Enter to enter UEFI: Built-in EFI Shell. Figure 3.1 Enter the storage disk where the AfuEfi64 package is stored, use cd commands to access to the AfuEfi64 folder, and BIOS.bin is the 32M BIOS+ME file to be updated.
  • Page 80 BIOS Setup Figure 3.3 When the ME part is updated, the 32M ME+BIOS upgrade command is: AfuEfix64.efi BIOS.bin /b /p /n /x /k /l /me, the refresh process is shown in the figure. Parameter Description: - /B Program Boot Block - /P Program main bios image - /N...
  • Page 81 Figure 3.4 Note: After the update is completed, please cut off the power and confirm that there is no power remaining on the board, then power it on again. BIOS 4.14.2 Upgrade under Linux system Linux OS uses afulnx tool to upgrade BIOS. The afulnx tool has 32-bit and 64-bit version. Take Linux 64bit OS as an example, use afulnx_64 tool to enter the directory of afulnx_64 tool, and put the corresponding BIOS bin file into this folder.
  • Page 82 BIOS Setup ./afulnx_64 BIOS.bin /b /p /n /x /k /l as shown in the following figure. Figure 3.4 When the ME part is changed, you need to update the BIOS version and ME at the same time, execute the command: ./afulnx_64 BIOS.bin /b /p /n /x /k /l /me, BIOS.bin - the bin file of the BIOS to be updated as shown in the following figure.
  • Page 83: Bmc Settings

    This section introduces the specifications that the management software follows and its main functions. The Inspur Server Management System is a control unit for server management, which is compatible with the management standard IPMI2.0 specification. Below are the main functions of the Inspur Server Management System: ●...
  • Page 84: Functional Modules

    5.2.1 Module Composition The Inspur Server Management System is mainly composed of IPMI module, command line module, WEB module, KVM Over IP and virtual media. ●The command line module attains the calling of IPMI module. The user performs the operation on IPMI module via command lines.
  • Page 85: Web Module

    or CD/floppy disk iso file) in the form of virtual CD driver and floppy drive on server via the internet. To use the remote control function, the client should be equipped with appropriate browser and Java runtime environment. 5.3 Web Module The Web module can be accessed through browser;...
  • Page 86 BMC Settings 5.3.2 Web Interface Introduction The Web interface helps users accomplish server management. The Web interface also has a help function so users can click the help button in the case that they may need The Web interface is divided into several parts, as shown in the following figure.
  • Page 87 ● The name of the Web interface is displayed on top left of the interface. ● The meanings of all buttons on top right of the interface: Click on the Overview button, to return to the overview page.  Click on the Refresh button, to refresh the page. ...
  • Page 88 BMC Settings System configuration • For detailed introduction on all functions, please refer to the following chapters. ● Specific operation interface is on the right of the interface. 5.3.3 Overview Click on Overview to open the “General Information” interface, as shown below. 5.3.4 System Information Select “Information”...
  • Page 90: Storage

    BMC Settings 5.4 Storage Select “Storage” on the navigation tree to open the storage interface. At present, the storage information control only supports LSI RAID card. This interface contains controller, physical drives, and logical drives information, as shown in the following figures. 5.5 Remote Control Select “Remote Control”...
  • Page 92: Fan

    BMC Settings 5.6 Fan Select “Fan” on the navigation tree to open the fan interface. It contains the interfaces of fan speed control, as shown in the following figures. ● Fan speed control: Contains fan status, current speed and speed control function. Note: Fan speed control contains the following speed levels: Low: About 20% duty ratio ...
  • Page 93 ● LDAP/E-Directory Settings: Displayed table shows any configured Role Groups and available slots. You can modify or add/delete role groups from here. ● Users: Through the user settings interface, you can manage the BMC’s account, including adding users, deleting users, modifying user passwords. ●...
  • Page 94 BMC Settings...
  • Page 96: Logs

    BMC Settings 5.8 Logs Select “Logs” on the navigation tree to open the related log interface. It contains the interfaces of system event log, BMC system audit log, black box log, event log setting and system and audit log settings, as shown in the following figures. ●...
  • Page 98: Fault Diagnosis

    BMC Settings 5.9 Fault Diagnosis Select “Fault Diagnosis” on the navigation tree to open the fault diagnosis interface. It contains the interfaces of BMC self-inspection result, BMC recovery, capture screen and host POST code, as shown in the following figures. ●...
  • Page 99: System Maintenance

    5.10 System Maintenance Select “System Maintenance” on the navigation tree to open the system maintenance interface. It contains the interfaces of BMC firmware update, BIOS firmware update and restore factory defaults, as shown in the following figures. ●BMC firmware update: To update BMC FW via BMC Web interface. ●BIOS firmware update: To update BIOS FW via BMC Web interface.
  • Page 100: Service & Protocol

    BMC Settings 5.11 Service & Protocol The services or protocols supported by BMC include RCMP+, Http/Https, KVM, cd-media, fd- media, hd-media, ssh, and telnet. Users can choose to enable or disable these services, as well as configure the port number, session timeout and the maximum sessions. Non-secure Secure Port Default Port...
  • Page 101: User Management

    not update automatically, the page will be logged out when you switch the page or refresh the page. 2. Telnet is a non-secure protocol, if you do not use it, it is recommended to disable it. 5.12 User Management 5.12.1 IPMI User BMC supports IPMI2.0 user models, and supports up to 16 users.
  • Page 102: Bmc Firmware Update

    BMC Settings This function is disabled by default, and we strongly recommend that you enable this function for security reasons. If this function is enabled, the password needs to be changed before expiration. If the password expires, you will need to disable this function in the operating system via the OEM’s IPMI command.
  • Page 103 after 20 minutes timeout. When the image starts to flash, the watchdog timeout will be updated to 20 minutes again. Supports dual-image firmware update When updating the BMC firmware, the user can specify the image to update, you can choose: •...
  • Page 104: Time Zone Table

    BMC Settings 5.14 Time Zone Table Name of Time Zone Time Dateline Standard Time (GMT-12:00) International Date Line West Samoa Standard Time (GMT-11:00) Midway Island, Samoa Hawaiian Standard Time (GMT-10:00) Hawaii Alaskan Standard Time (GMT-09:00) Alaska Pacific Standard Time (GMT-08:00) Pacific Time (US and Canada); Tijuana Mountain Standard Time (GMT-07:00) Mountain Time (US and Canada) Mexico Standard Time 2...
  • Page 105 Israel Standard Time (GMT+02:00) Jerusalem South Africa Standard Time (GMT+02:00) Harare, Pretoria Russian Standard Time (GMT+03:00) Moscow, St. Petersburg, Volgograd Arab Standard Time (GMT+03:00) Kuwait, Riyadh E. Africa Standard Time (GMT+03:00) Nairobi Arabic Standard Time (GMT+03:00) Baghdad Iran Standard Time (GMT+03:30) Tehran Arabian Standard Time (GMT+04:00) Abu Dhabi, Muscat...
  • Page 106: Common Faults, Diagnosis And Troubleshooting

    If there is a machine and a power module of the same type, you could change the power module to test whether there is a power module fault. If the instructions above do not resolve the problem, please contact Inspur customer service.
  • Page 107 When tested in a non-system situation, if the keyboard or mouse performance turns out to be normal, a system fault could be considered. If the keyboard or mouse fault still exists, a mainboard interface fault could be considered, and Inspur technical hotline can be called for support.
  • Page 108: Software Problems

    Advanced System Property-> Advanced-> Performance-> Settings-> Change Virtual Memory, turn down the virtual memory or allocate the virtual memory to other partitions. If above operations could not resolve the problem, please contact Inspur customer service. 2) The memory capacity is abnormal...
  • Page 109 4G memory at most. If the memory is not identified completely in BIOS Setup, confirm that the corresponding slots have been installed with memories of correct type. If above operations could not resolve the problem, please contact Inspur customer service. 3) Abnormal network...
  • Page 110: Battery Replacement

    Remove the full-length expansion board retainer if any full-length expansion boards are installed. Remove the PCI riser cage. Remove the air baffle. Remove the battery. To replace the component, reverse the removal procedure. For more information about battery replacement or proper disposal, contact Inspur Customer Service.
  • Page 111: Regulatory Compliance Notices

    8 Regulatory Compliance Notices 8.1 Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information.
  • Page 112: Cables

    Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to Inspur, an authorized Inspur Partner, or their agents.
  • Page 113: Electrostatic Discharge

    Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact Inspur Customer Service.
  • Page 114: Warranty

    Customers could return defective parts to the designated Inspur site after submitting a service request. Inspur may, at its discretion, repair or replace the defective parts. Repair or replacement parts may be new, used, or equivalent to new in performance and reliability.
  • Page 115: Warranty Exclusions

    10.3 Warranty Exclusions Inspur does not guarantee that there will be no interruptions or mistakes during the use of the products. Inspur will not undertake any responsibility for the losses arising from any operation not conducted according to Inspur Hardware Products.