Fault Logging - Analog Devices Linear LTM 4700 User Manual

Dual 50a or single 100a µmodule regulator with digital power system management
Table of Contents

Advertisement

LTM4700
PMBus COMMAND DETAILS

Fault Logging

COMMAND NAME
CMD CODE DESCRIPTION
MFR_FAULT_LOG
MFR_FAULT_LOG_ STORE
MFR_FAULT_LOG_CLEAR
MFR_FAULT_LOG
The MFR_FAULT_LOG command allows the user to read the contents of the FAULT_LOG after the first fault occur-
rence since the last MFR_FAULT_LOG_CLEAR command was written. The contents of this command are stored in
non-volatile memory, and are cleared by the MFR_FAULT_LOG_CLEAR command. The length and content of this
command are listed in Table 15. If the user accesses the MFR_FAULT_LOG command and no fault log is present, the
command will return a data length of 0. If a fault log is present, the MFR_FAULT_LOG will return a block of data 147
bytes long. If a fault occurs within the first second of applying power, some of the earlier pages in the fault log may
not contain valid data.
NOTE: The approximate transfer time for this command is 3.4ms using a 400kHz clock.
This read-only command is in block format.
MFR_FAULT_LOG_STORE
The MFR_FAULT_LOG_STORE command forces the fault log operation to be written to NVM just as if a fault event
occurred. This command will set bit 3 of the STATUS_MFR_SPECIFIC fault if bit 7 "Enable Fault Logging" is set in
the MFR_CONFIG_ALL command.
If the die temperature exceeds 130°C, the MFR_FAULT_LOG_STORE command is disabled until the IC temperature
drops below 125°C.
This write-only command has no data bytes.
116
0xEE
Fault log data bytes.
0xEA
Command a transfer of the fault log from RAM
to EEPROM.
0xEC
Initialize the EEPROM block reserved for fault
logging.
For more information
TYPE
PAGED
R Block
N
Send Byte
N
Send Byte
N
www.analog.com
DATA
DEFAULT
FORMAT UNITS
NVM
VALUE
Reg
Y
NA
NA
NA
Rev. B