PMBus COMMAND DETAILS
Table 16. IOUT_OC_FAULT_RESPONSE Data Byte Contents
BITS
DESCRIPTION
7:6
Response
For all values of bits [7:6], the LTM4700:
• Sets the corresponding fault bit in the status commands and
• Notifies the host by asserting ALERT pin, unless masked.
The fault bit, once set, is cleared only when one or more of the
following events occurs:
• The device receives a CLEAR_FAULTS command.
• The output is commanded through the RUN pin, the OPERATION
command, or the combined action of the RUN pin and
OPERATION command, to turn off and then to turn back on, or
• The device receives a RESTORE_USER_ALL command.
• The device receives a MFR_RESET command.
• The device supply power is cycled.
5:3
Retry Setting
2:0
Delay Time

Fault Responses IC Temperature

COMMAND NAME
CMD CODE DESCRIPTION
MFR_OT_FAULT_
RESPONSE
MFR_OT_FAULT_RESPONSE
The MFR_OT_FAULT_RESPONSE command byte instructs the device on what action to take in response to an internal
overtemperature fault. The data byte is in the format given in Table 12.
The LTM4700 also:
• Sets the NONE_OF_THE_ABOVE bit in the STATUS_BYTE
• Sets the MFR bit in the STATUS_WORD, and
• Sets the Overtemperature Fault bit in the STATUS_MFR_SPECIFIC command
• Notifies the host by asserting ALERT pin, unless masked
This command has one data byte.
0xD6
Action to be taken by the device when an
internal overtemperature fault is detected.
For more information
VALUE
MEANING
00
The LTM4700 continues to operate indefinitely while
maintaining the output current at the value set by
IOUT_OC_FAULT_LIMIT without regard to the output
voltage (known as constant-current or brick-wall limiting).
01
Not supported.
10
The LTM4700 continues to operate, maintaining the output
current at the value set by IOUT_OC_FAULT_LIMIT without
regard to the output voltage, for the delay time set by bits [2:0].
If the device is still operating in current limit at the end of the
delay time, the device responds as programmed by the Retry
Setting in bits [5:3].
11
The LTM4700 shuts down immediately and responds as
programmed by the Retry Setting in bits [5:3].
000
The unit does not attempt to restart. The output remains
disabled until the fault is cleared by cycling the RUN pin or
removing bias power.
111
The device attempts to restart continuously, without limitation,
until it is commanded OFF (by the RUN pin or OPERATION
command or both), bias power is removed, or another fault
condition causes the unit to shut down. Note: The retry interval
is set by the MFR_RETRY_DELAY command.
000-111 The number of delay time units in 16ms increments. This
delay time is used to determine the amount of time a unit is
to continue operating after a fault is detected before shutting
down. Only valid for deglitched off response.
TYPE
PAGED
FORMAT
R Byte
N