Analog Devices Linear LTM 4700 User Manual page 70

Dual 50a or single 100a µmodule regulator with digital power system management
Table of Contents

Advertisement

LTM4700
APPLICATIONS INFORMATION
Do not put vias directly on pads, unless they are capped
n
or plated over.
Use a separate SGND copper plane for components
n
connected to signal pins. Connect SGND to GND local
to the LTM4700.
Use Kelvin sense connections across the input R
n
resistor if input current monitoring is used.
70
SENSE
TOP LAYER
V
OUT1
GND
V
IN1
GND
BOTTOM LAYER
V
OUT1
GND
GND
Figure 45. Recommended PCB Layout Package Top View
For more information
For parallel modules, tie the V
n
voltage-sense differential pair lines, RUNn, , COMPna,
COMP
pin together. The user must share the SYNC,
nb
SHARE_CLK, FAULT, and ALERT pins of these parts. Be
sure to use pull-up resistors on FAULT, SHARE_CLK
and ALERT.
Bring out test points on the signal pins for monitoring.
n
Figure 45 gives a good example of the recommended layout.
V
OUT0
GND
V
IN0
GND
V
OUT0
GND
GND
4700 F45
www.analog.com
+
, ,V
/V
OUTn
OSNSn
OSNSn
Rev. B

Advertisement

Table of Contents
loading

Table of Contents