PMBus COMMAND DETAILS
TON_MAX_FAULT_LIMIT
The TON_MAX_FAULT_LIMIT command sets the value, in milliseconds, on how long the unit can attempt to power
up the output without reaching the output undervoltage fault limit.
A data value of 0ms means that there is no limit and that the unit can attempt to bring up the output voltage indefinitely.
The maximum limit is 83 seconds.
This command has two data bytes and is formatted in Linear_5s_11s format.
VOUT_TRANSITION_RATE
When a PMBus device receives either a VOUT_COMMAND or OPERATION (Margin High, Margin Low) that causes the
output voltage to change this command set the rate in V/ms at which the output voltage changes. The commanded
rate of change does not apply when the unit is commanded on or off. The maximum allowed slope is 4V/ms.
This command has two data bytes and is formatted in Linear_5s_11s format.
Timing—Off Sequence/Ramp
COMMAND NAME
CMD CODE DESCRIPTION
TOFF_DELAY
TOFF_FALL
TOFF_MAX_WARN_LIMIT
TOFF_DELAY
The TOFF_DELAY command sets the time, in milliseconds, from when a stop condition is received until the output
voltage starts to fall. Values from 0 to 83 seconds are valid. The resulting turn off delay will have a typical delay of
270µs for TOFF_DELAY = 0 and an uncertainty of ±50µs for all values of TOFF_DELAY. TOFF_DELAY is not applied
when a fault event occurs
This command has two data bytes and is formatted in Linear_5s_11s format.
TOFF_FALL
The TOFF_FALL command sets the time, in milliseconds, from the end of the turn-off delay time until the output volt-
age is commanded to zero. It is the ramp time of the V
set to high impedance state.
The part will maintain the mode of operation programmed. For defined TOFF_FALL times, the user should set the part
to continuous conduction mode. Loading the max value indicates the part will ramp down at the slowest possible rate.
The minimum supported fall time is 0.25ms. A value less than 0.25ms will result in a 0.25ms ramp. The maximum
fall time is 1.3 seconds. The number of steps in TOFF_FALL is equal to TOFF_FALL (in ms)/0.1ms with an uncertainty
of ±0.1ms.
In discontinuous conduction mode, the controller will not draw current from the load and the fall time will be set by
the output capacitance and load current.
This command has two data bytes and is formatted in Linear_5s_11s format.
0x64
Time from RUN and/or Operation off to
the start of TOFF_FALL ramp.
0x65
Time from when the output starts to fall
until the output reaches zero volts.
0x66
Maximum allowed time, after TOFF_FALL
completed, for the unit to decay below
12.5%.
For more information
TYPE
PAGED
R/W Word
Y
R/W Word
Y
R/W Word
Y
DAC. When the V
OUT
OUT
www.analog.com
LTM4700
DATA
FORMAT
UNITS
NVM
L11
ms
Y
L11
ms
Y
L11
ms
Y
DAC is zero, the PWM output will be
DEFAULT
VALUE
0.0
0x8000
8.0
0xD200
150
0xF258
Rev. B
93