LTM4700
PMBus COMMAND DETAILS
READ_VIN
The READ_VIN command returns the measured V
pin voltage, in volts added to READ_ICHIP • MFR_RVIN. This
IN
compensates for the IR voltage drop across the V
filter element due to the supply current of the LTM4700.
IN
This read-only command has two data bytes and is formatted in Linear_5s_11s format.
READ_VOUT
The READ_VOUT command returns the measured output voltage by the VOUT_MODE command.
This read-only command has two data bytes and is formatted in Linear_16u format.
READ_IIN
The READ_IIN command returns the input current, in Amperes, as measured across the input current sense resistor
(see also MFR_IIN_CAL_GAIN).
This read-only command has two data bytes and is formatted in Linear_5s_11s format.
READ_IOUT
The READ_IOUT command returns the average output current in amperes. The IOUT value is a function of:
a) the differential voltage measured across the I
pins
SENSE
b) the IOUT_CAL_GAIN value
c) the MFR_IOUT_CAL_GAIN_TC value, and
d) READ_TEMPERATURE_1 value
e) The MFR_TEMP_1_GAIN and the MFR_TEMP_1_OFFSET
This read-only command has two data bytes and is formatted in Linear_5s_11s format.
READ_TEMPERATURE_1
The READ_TEMPERATURE_1 command returns the temperature, in degrees Celsius, of the external sense element.
This read-only command has two data bytes and is formatted in Linear_5s_11s format.
READ_TEMPERATURE_2
The READ_TEMPERATURE_2 command returns the LTM4700's die temperature, in degrees Celsius, of the internal
sense element.
This read-only command has two data bytes and is formatted in Linear_5s_11s format.
READ_FREQUENCY
The READ_FREQUENCY command is a reading of the PWM switching frequency in kHz.
This read-only command has 2 data bytes and is formatted in Linear_5s_11s format.
READ_POUT
The READ_POUT command is a reading of the DC/DC converter output power in Watts. POUT is calculated based on
the most recent correlated output voltage and current reading.
This read-only command has 2 data bytes and is formatted in Linear_5s_11s format.