LTM4700
PMBus COMMAND DETAILS
STATUS_MFR_SPECIFIC
The STATUS_MFR_SPECIFIC commands returns one byte with the manufacturer specific status information.
The format for this byte is:
BIT
MEANING
7
Internal Temperature Fault Limit Exceeded.
6
Internal Temperature Warn Limit Exceeded.
5
Factory Trim Area NVM CRC Fault.
4
PLL is Unlocked
3
Fault Log Present
2
V
UV or OV Fault
DD33
1
ShortCycle Event Detected
0
FAULT Pin Asserted Low by External Device
If any of these bits are set, the MFR bit in the STATUS_WORD will be set, and ALERT may be asserted.
The user is permitted to write a 1 to any bit in this command to clear a specific fault. This permits the user to clear
status by means other than using the CLEAR_FAULTS command. However, the fault log present bit can only be cleared
by issuing the MFR_FAULT_LOG_CLEAR command.
Any supported fault bit in this command will initiate an ALERT event.
This command has one data byte.
MFR_PADS
This command provides the user a means of directly reading the digital status of the I/O pins of the device. The bit
assignments of this command are as follows:
BIT
ASSIGNED DIGITAL PIN
15
V
OV Fault
DD33
14
V
UV Fault
DD33
13
Reserved
12
Reserved
11
ADC Values Invalid, Occurs During Start-Up. May Occur Briefly on Current Measurement Channels During Normal Operation
10
SYNC clocked by external device (when LTM4700 configured to drive SYNC pin)
9
Channel 1 Power Good
8
Channel 0 Power Good
7
LTM4700 Driving RUN1 Low
6
LTM4700 Driving RUN0 Low
5
RUN1 Pin State
4
RUN0 Pin State
3
LTM4700 Driving FAULT1 Low
2
LTM4700 Driving FAULT0 Low
1
FAULT1 Pin State
0
FAULT0 Pin State
A 1 indicates the condition is true.