PMBus COMMAND DETAILS
This condition is detected by the ADC so the response time may be up to t
This command has one data byte.
Table 18. Data Byte Contents: TON_MAX_FAULT_RESPONSE, VIN_OV_FAULT_RESPONSE,
OT_FAULT_RESPONSE, UT_FAULT_RESPONSE
BITS
DESCRIPTION
7:6
Response
For all values of bits [7:6], the LTM4700:
• Sets the corresponding fault bit in the status commands, and
• Notifies the host by asserting ALERT pin, unless masked.
The fault bit, once set, is cleared only when one or more of the
following events occurs:
• The device receives a CLEAR_FAULTS command.
• The output is commanded through the RUN pin, the OPERATION
command, or the combined action of the RUN pin and
OPERATION command, to turn off and then to turn back on, or
• The device receives a RESTORE_USER_ALL command.
• The device receives a MFR_RESET command.
• The device supply power is cycled.
5:3
Retry Setting
2:0
Delay Time

FAULT SHARING

Fault Sharing Propagation

COMMAND NAME
CMD CODE DESCRIPTION
MFR_FAULT_
0xD2
PROPAGATE
MFR_FAULT_PROPAGATE
The MFR_FAULT_PROPAGATE command enables the faults that can cause the FAULTn pin to assert low. The com-
mand is formatted as shown in Table 16. Faults can only be propagated to the FAULTn pin if they are programmed to
respond to faults.
This command has two data bytes.
Configuration that determines which faults
are propagated to the FAULT pins.
For more information
.
CONVERT
VALUE
MEANING
00
The PMBus device continues operation without interruption.
01
Not supported. Writing this value will generate a CML fault.
10
The device shuts down immediately (disables the output) and
responds according to the retry setting in bits [5:3].
11
Not supported. Writing this value will generate a CML fault.
000
The unit does not attempt to restart. The output remains
disabled until the fault is cleared until the device is commanded
OFF bias power is removed.
111
The PMBus device attempts to restart continuously, without
limitation, until it is commanded OFF (by the RUN pin or
OPERATION command or both), bias power is removed, or
another fault condition causes the unit to shut down without
retry. Note: The retry interval is set by the MFR_RETRY_DELAY
command.
XXX
Not supported. Values ignored
TYPE
PAGED
R/W Word
Y
www.analog.com
LTM4700
DATA
DEFAULT
FORMAT
UNITS
NVM
VALUE
Reg
Y
0x6993
101
Rev. B