Turbofiller Adjustment; Cyclonefilter - Hardi AEON CENTURA TWIN FORCE Instruction Book

Table of Contents

Advertisement

TurboFiller Adjustment

The TurboFiller can be adjusted in working height and the spring load
applied when you pull/push it out/in from storage to working position.
A. Select working height by moving the bolt between the two holes.
B. Select spring load by moving the bolt between the three holes.

CycloneFilter

Check the following before use:
• Set the boost valve (B) for the actual use. See "CycloneFilter" on
page 52.
• The standard filter size is 80 mesh and can be changed by opening
the filter top.
• Check condition of O-rings and lubricate if necessary, or replace
them if damaged, before reassembly. See "10 Hours Service -
CycloneFilter" on page 155.
DANGER! Never open the CycloneFilter unless pressing
to close the pump suction and pressing
to the MainTank!
In addition, turn the boost valve (B) to the closed position.
Otherwise spraying liquid may hit you, when opening the filter
and thereby draining the MainTank!
to enable return
4 - Sprayer Setup
91