5 - Operation
75
50
22. Press
%
%
,
23. Press
to leave the AutoFill or Agitation menu.
24. Press
to enter the Fluid Functions menu.
25. Press
to enable suction from the RinseTank or press
26. Flush the TurboFiller with clean water by pressing the TurboFiller
hopper-rinsing button for at least 30 seconds.
μ
ATTENTION! If not shifted to suction from a clean water supply,
the hopper-rinsing device uses spray liquid for rinsing the
hopper!
μ
ATTENTION! Always clean the TurboFiller, when the spray job is
ended, and together with cleaning the entire sprayer. A cleaning
after the last filling, and before spraying, does not ensure a clean TurboFiller!
27. The TurboFiller suction valve (C) must be open for at least 20 seconds after the rinse water is no longer visible in the
hopper, in order to empty the transfer hoses completely into the MainTank.
28. When the hopper rinsing end, close the TurboFiller suction valve (C).
29. Press
to direct fluid to the MainTank.
30. Disconnect the suction hose and replace the cap.
±
WARNING! If carrying the suction hose/filter on the sprayer during spraying, spray drift can contaminate it, which will
transfer to lake/river when filling!
μ
ATTENTION! Observe local legislation regarding use of filling device. In some areas, filling from open water reservoirs
(lakes, rivers etc.) prohibited. It is strongly recommended only to fill from closed reservoirs (mobile water tanks etc.)
to prevent contamination.
31. When the spray liquid is well agitated, press
spraying of the crop.
128
25
OFF
%
,
or
to set at a suitable agitation level.
to enable suction from an external tank.
to enable spraying. If necessary, continue agitation during