Service Menu - Hardi AEON CENTURA TWIN FORCE Instruction Book

Table of Contents

Advertisement

3 - Description

Service Menu

The FluidBox 8000 display, located in the WorkZone, fully controls the fluid valves. Identification buttons distinguish the
possible functions of the fluid valves.
The service screen show following status:
A. Flow per nozzle.
B. Spray pressure.
C. Actual PTO revolutions.
D. Not Active.
E. Selected gravity of the liquid filled into the
MainTank.
F. Not Active.
G. Actual agitation level.
H. Actual MainTank contents.
I. Actual RinseTank contents.
J. Spray pressure.
Activate a function by pressing the button for the desired function. The button become green when the function is selected
and active.
Function Menus on Left Side of Display
The buttons select the suction source from where the pump will use liquid.
Symbol
Symbol Description
Check the suction from the MainTank.
Check the suction from the RinseTank.
Open/close the spray nozzles.
Function Menus on Right Side of Display
The buttons select the pressure function the pump will direct the liquid to.
Symbol
Symbol Description
Back to previous menu.
Set the agitation level in the MainTank.