AutoFill and Fill Liquid Chemicals Using the TurboFiller

μ
ATTENTION! We advice to use the TurboFiller, when you fill chemicals on the sprayer.
1. Remove the cap for
suction coupler.
2. Press
to enter the AutoFill menu.
Q
3. Press
to enter the MainTank contents wanted after the
filling procedure has ended.
4. After entering the quantity, the screen will
show the MainTank contents wanted after
the filling procedure has ended (A).
5. Engage the pump and set PTO revolutions at
max. 540 RPM or 1000 RPM depending on
pump model.
6. Press
to AutoFill the MainTank. This
set the fluid valves for their correct positions
and start the filling process.
DANGER! Before pressing
important to ensure that the PressureEmpty
quick coupler lid
completely fitted to the filling coupler into
its locked position. Failure to do so may cause risk of contamination and injury from the PressureEmpty quick coupler
lid being "shot" off when pressurized! If not possible to fit the quick coupler lid completely, lubricate the rubber seal
and the grip hooks.
7. Keep an eye on the top window (B) in the display for filling status.
8. Fill the MainTank at least 1/3 with water (unless otherwise stated on the chemical container label).
±
WARNING! Do not leave the sprayer while filling the tank. Keep an eye on the top window (B) in the display for filling
status.
9. Open the TurboFiller lid.
10. Open the TurboDeflector valve.
and connect a suction hose to the
, it is very
is correct and
5 - Operation