Mechanical Connections

Drawbars

The low hitch drawbar can be delivered with different coupling parts.
Following drawbar hitches are available for low tractor hitch points:
A. Low D50/33 swivel
B. Low K80 ball coupler

Hose Package Support

To prevent hoses and wiring from being damaged by the tractor wheels
or the PTO shaft, all hoses, cables and wires are held by the hose package
support fitted to the sprayer platform.
The bracket (A) is for the storing of hydraulic and electric connectors etc.
when the sprayer is disconnected from the tractor. The height of the
bracket can be adjusted by the means of the bolts (B).
μ
ATTENTION! A sprayer with steering requires more slack in the
cables. Make sure that the hoses and cables are long enough in
tight turns, when fully steered.

ComfortTrack Steering Potentiometer Connection

When connecting the ComfortTrack sprayer to the tractor it is important
to set up the front potentiometer on the drawbar correctly. The
potentiometer must be connected to the tractor with the supplied two
chains.
To ensure a high precision,
• the chains must be parallel and horizontal.
• the tractor hitch point must not have any sidewards movement.
Refer to part "Tractor Installation" in the SmartCom ISOBUS UT
instruction book for setup procedure.Procedure when connecting the
sprayer to the tractor:
1. Connect the sprayer.
2. Drive forward with the sprayer following the tractor in a straight line, and then stop.
3. Connect the two chains for the potentiometer, while ensuring that the transverse potentiometer bar is perpendicular
to the drawbar. The chains must be parallel and horizontal, as well as tightened, so that the torsion levers (A) are vertical.
4. Enter the controller menu. Check if the front potentiometer is reading 2.50 volts in the centre position.
• HC 6500 / ISOBUS VT: [Menu 4.5.4.6 Track Sensor Test]. Check if the front sensor reading is 2.50 volts.
5. If the voltage reading is not correct, then adjust the chain connection until voltage = 2.50 volts.
Allowable deviation is ±0.05 volts.
6. Fine-tuning is carried out by loosening the screws for the potentiometer.