Hardi AEON CENTURA TWIN FORCE Instruction Book page 132

Table of Contents

Advertisement

5 - Operation
TurboFiller Hopper Rinsing - TurboFiller Lid is Closed
1. Close TurboFiller lid.
2. To flush the TurboFiller with clean water, press
enable suction of clean water from an external tank.
3. Engage the hopper transfer device by opening the TurboFiller
suction valve (A) to transfer the rinse water to the MainTank.
4. Open the Turbo Deflector Valve for 1 minute to get plenty of clean
water through the hoses.
5. Press the hopper rinsing valve
the rotating flushing nozzle (B), while the rinsing liquid is emptied
out of the TurboFiller.
6. Rinse the hopper for 30-40 seconds.
7. Open the lid to inspect if the TurboFiller is empty. If not, wait until
the TurboFiller is empty.
8. After the last flushing, the TurboFiller suction valve (A) must be
open for at least 20 seconds, after the rinse water is no longer
visible in the hopper, in order to completely empty the transfer
hoses into the main tank.
μ
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying. This is to ensure that it is clean,
before spraying other crops that may be sensitive to the chemicals just used. See the section "Cleaning" on page 136
for details.
132
to enable suction from the RinseTank or press
. This rinses the hopper with
to