13. Place the container over the chemical container-rinsing nozzle (B)
in the left side of the TurboFiller. Then push to rinse the inside of
the container.
μ
ATTENTION! The rinsing device uses spray liquid to rinse
containers for concentrated chemicals. Before disposal, always
rinse the chemical containers with clean water several times, until
they are clean.
14. Close the TurboFiller lid.
15. Press
to enable suction from the RinseTank or press
16. Flush the TurboFiller with clean water by pressing the TurboFiller
hopper-rinsing button for at least 30 seconds.
μ
ATTENTION! If not shifted to suction from a clean water supply,
the hopper-rinsing device uses spray liquid for rinsing the
hopper!
μ
ATTENTION! Always clean the TurboFiller, when the spray job is
ended, and together with cleaning the entire sprayer. A cleaning
after the last filling, and before spraying, does not ensure a clean TurboFiller!
μ
The TurboFiller suction valve (A) must be open for at least 20 seconds after the rinse water is no longer visible in the
hopper, in order to empty the transfer hoses completely into the MainTank.
17. When the hopper rinsing end, close the TurboFiller suction valve (A).
18. Press
to enter the agitation menu.
19. Press
100
to open the agitation valve.
%
μ
ATTENTION! If foaming is a problem, reduce the agitation level.
20. When the spray liquid is well agitated, press
crop.
to enable suction from an external tank.
to enable spraying. Continue agitation during spraying of the
5 - Operation