Hardi AEON CENTURA TWIN FORCE Instruction Book page 123

Table of Contents

Advertisement

25. Flush the TurboFiller with clean water by pressing the TurboFiller
hopper-rinsing button for at least 30 seconds.
μ
ATTENTION! If not shifted to suction from a clean water supply,
the hopper-rinsing device uses spray liquid for rinsing the
hopper!
μ
ATTENTION! Always clean the TurboFiller, when the spray job is
ended, and together with cleaning the entire sprayer. A cleaning
after the last filling, and before spraying, does not ensure a clean TurboFiller!
26. The TurboFiller suction valve (C) must be open for at least 20 seconds after the rinse water is no longer visible in the
hopper, in order to empty the transfer hoses completely into the MainTank.
27. When the hopper rinsing end, close the TurboFiller suction valve (C).
28. Press
to direct fluid to the MainTank.
29. Disconnect the suction hose and replace the cap.
±
WARNING! If carrying the suction hose/filter on the sprayer during spraying, spray drift can contaminate it, which will
transfer to lake/river when filling!
μ
ATTENTION! Observe local legislation regarding use of filling device. In some areas, filling from open water reservoirs
(lakes, rivers etc.) prohibited. It is strongly recommended only to fill from closed reservoirs (mobile water tanks etc.)
to prevent contamination.
30. When the spray liquid is well agitated, press
spraying of the crop.
to enable spraying. If necessary, continue agitation during
5 - Operation
123

Advertisement

Table of Contents
loading

Table of Contents