3 - Description

TurboFiller

The TurboFiller is where you add the chemicals to be mixed with water in the main tank.
Capacity: approximately 25 litres.
Before Use
• Pull the handle (arrow) to unlock.
• Grab the handle to pull the TurboFiller down, until it clicks into
locked position.
After Use
• Push the TurboFiller back in storing position, until it locks.
±
WARNING! Before releasing the lock, always keep a hand on the
grip to avoid abrupt movement of the TurboFiller!
TurboFiller Suction Valve
The valve is used simultaneously with the TurboFiller. The valve has 2
settings: Continuously open or spring-loaded normally closed.
Open the valve by lifting the lever up, when chemicals are to be filled
into the TurboFiller and transferred to main tank.
TurboDeflector Valve
This TurboDeflector valve activates the vortex flushing of the TurboFiller.
Lift the lever to lock it in open position for continuous liquid rotation in
the hopper.
Rinsing of Chemical Containers
The upper lever is used for two purposes.
1. When the TurboFiller lid is open:
For rinsing empty containers. Place the container over the rotating
flushing nozzle in the middle of the TurboFiller to rinse the inside
of the container.
2. When the TurboFiller lid is closed:
Use the lever to rinse the hopper, when the filling of chemicals is
completed.
DANGER! Do not activate this lever, unless the multi-hole nozzle is covered by a container, as spray liquid may
otherwise hit the operator! Risk of injuries and spillage on the ground.