Greasing The Pump - Hardi AEON CENTURA TWIN FORCE Instruction Book

Table of Contents

Advertisement

6 - Maintenance

Greasing the Pump

Grease the pump as follows:
• Factory greased:
300 g grease into each lubrication point (A).
• Normal operation:
Greasing every 50 hours with 30 grams of grease into each
lubrication point (A). Also refer to "50 Hours Service -
Greasing the Pump" on page 157.
• After disassembling the pump (diaphragm renewal, etc.):
Greasing with 200 grams of grease into each lubrication
point (A).
μ
ATTENTION! In order to prevent excessive wear, it is important to
use a recommended lubricant! See the section "Recommended
Lubricants" in this book.
μ
ATTENTION! When greasing the pump MUST be stopped!