Rinsing of TurboFiller Hopper
Use the upper lever for rinsing the hopper, when the filling of chemicals
is completed and the lid (A) is closed.
DANGER! Do not activate this lever, unless closing the TurboFiller
lid (A), as spray liquid may otherwise hit the operator! Risk of
injuries and spillage on the ground.
TurboDeflector Valve
This TurboDeflector valve activates the vortex flushing of the TurboFiller.
Push the lever for liquid rotation in the hopper.
Rinsing of Chemical Containers
Use the valve for rinsing empty containers.
Enable the push-activated chemical container-rinsing nozzle (B), by
lifting the lever up. Place the container over the rotating flushing nozzle
(B) in the left side of the TurboFiller. Then push to rinse the inside of the
container.
After Use
• Clean the inside of the TurboFiller with the spray gun (G) to remove
chemical residues.
• Place the spray gun in its storing position on the left side of the
TurboFiller.
• Close the TurboFiller lid (D).
• Press
to rinse the TurboFiller hopper.
• Grab the handle (B) and push the TurboFiller upwards (E).
• Raise the TurboFiller to the storage position and let go of the
locking lever to lock the position.