Mechanical installation
42
5.9.2

Optical speed measuring system

Axial alignment
There are markers in the optical sensor for axial
alignment (orientation lines). When installed, the slotted
disc should be exactly above these alignment lines.
Divergence of up to ±2 mm is permissible in measuring
mode (total of static and dynamic shift).
Fig. 5.14
Position of the slotted disc in the speed sensor
A0785-150 HBM: public
Slotted disc
Alignment lines
T10FS