HBM T10FS Mounting Instructions page 41

Hide thumbs Also See for T10FS:
Table of Contents

Advertisement

Measuring range
Radial nominal distance
in mm
Actuation distance range
in mm
T10FS
Check the radial distance with a distance gauge and
compensate for any possible misalignment of the stator
by putting adjusting washers underneath or by adjusting
the base of the stator. You can also use the central
fastening screw on the sensor head for fine adjustments
(setting range ±1.5 mm).
100 NVm ... 3 kNVm
1.0
0.3 ... 1.8
Fig. 5.12
Radial nominal distance for the magnetic speed
measuring system
Fig. 5.13
Central fastening screw on the sensor head
1. Loosen the fastening screw (do not remove it!).
2. Set nominal distance a.
3. Tighten the screw at approx. 3 N⋅m.
4. Check the radial distance once again with a distance
gauge.
A0785-150 HBM: public
Mechanical installation
5 kNVm/10 kNVm
1.2
0.3 ... 2.2
Central fastening screw
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T10s2T10s3T10s4T10s5T10s6

Table of Contents