Option 2, Code Kf1; Adaptation To The Cable Length - HBM T10FS Mounting Instructions

Hide thumbs Also See for T10FS:
Table of Contents

Advertisement

Electrical connection
Binder 723
6
1
5
7
2
3
4
Top view
48
6.3

Option 2, code KF1

The stator housing has a 7‐pin (Binder 723) device
connector, to which you link the connection cable for
voltage supply and torque signal.
Conn.
Assignment
Binder
Pin
1
Supply voltage zero
2
No function
3
Pre‐amplifier supply
voltage (+15 V)
4
Torque measurement
signal (12 V
5...15 kHz)
5
No function
6
Rotor excitation voltage
(54 V/80 V
approx.15 kHz)
7
Rotor excitation voltage
(0 V)
Shielding connected to
housing ground
6.3.1

Adaptation to the cable length

The transmission method between the rotor and the
stator determines the function of the torque flange, which
is dependent on:
S the installation situation (for example, covering, area
free of metal parts)
S the length of the cable
A0785-150 HBM: public
;
PP
;
PP
Wire
MS3106
color
conn.
Pin
wh
A
bk
B
bu
C
rd
D
gn
F
gy
G