Setting The Pulse Count; Magnetic Speed Measuring System - HBM T10FS Mounting Instructions

Hide thumbs Also See for T10FS:
Table of Contents

Advertisement

Settings
Switches
S1...S4
64
8.5

Setting the pulse count

8.5.1

Magnetic speed measuring system

With the magnetic speed measuring system, a
magnetized rotor is sampled by means of an MR sensor
(magnetoresistive sensor). The sensor produces two
sinusoidal signals offset by 90_, from which up to 10
evaluation points can be generated per pole (can be
adjusted with switches F1 ... F3). The output pulses can
again be divided by means of the subsequent electronic
system (switches S1 ... S4), thus making available a
greater selection of output pulse counts per revolution
(see Fig. 8.8).
Fig. 8.7
Setting the pulse count; magnetic speed measuring
system
A0785-150 HBM: public
Switches
F1...F3
T10FS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T10s2T10s3T10s4T10s5T10s6

Table of Contents