ENGINE SHUTDOWN

NOTICE!
• Stopping the engine before it cools can
accelerate engine component wear. Never
abruptly shut down the engine except in an
emergency.
• Never stop the engine suddenly when it is
overheated. Run the engine at low idle to
allow it to cool down gradually before
shutting it down.
Failure to follow this notice could result in
damage to the machine or cause it to operate
improperly.
NOTE: Illustrations in this section show a cab
machine. Canopy machines are similar.
1. Park the machine on a firm, level surface.
2. Lower the bucket or optional equipment to the ground.
3. Adjust the throttle control dial (1) to MIN (low idle)
position and allow the engine to idle for 5 minutes to
cool down.
4. Turn the key switch (2) to the OFF position and remove
the key. Pull the hydraulic lockout control lever (3) back
to the locked (closed) position.
SANY
Fig. 4-19
Fig. 4-20
Operation and Maintenance Manual — 0120
Machine Operation
1
2
0002782
3
0002781
4-23